Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-40.5/42.7
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd., Livermore, CA
Resident Engineer: Mahfual Alam Structure Rep.: Unknown
DIME Sample ID: 2026-05-15-63
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2026
The quantity of what the sample constitutes: 2 BOXES, 132.32 TONS
A brief description of the sample: 3/4 RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Orange
HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 49R003ARSPWEO
Binder content (%): 7.5
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier: World Oil
RAP content (%): 0
WMA Additives: No
Antistrip type: 0.25% INGEVITY EVOTHERM
DIME Test ID: 2026-05-15-63-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/05/2026
Date Tested: 05/22/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
7.89 %
|
|
Mass of HMA Sample prior to ignition
|
2138 g
|
|
Mass Loss
|
177.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.31 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.11 %
|
|
Test Temperature
|
538 C
|