Print Report | Back to Sample Detail

Sample Record for 2026-05-27-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-32-5.0/10.2
Work Description: REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS
Location Description: BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32
Contractor Name: BALDWIN CONTRACTING COMPANY, INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 SKYWAY, CHICO CA 95928
Resident Engineer: Husam Makhoul Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-05-27-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/28/2026
The quantity of what the sample constitutes: 765
A brief description of the sample: A325 Bolt
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AFC Industries

Material Information

Rocap Number(s): NA
Heat Number(s): 1000132813
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: A325
Bolt Length(s): 3-1/4
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 1-1/4
Bolt Mfg. Lot Number: W000316786
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA
Washer Inner Diameter(s): NA

Test Results

Test

DIME Test ID: 2026-05-27-17-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Pitch Diameter 1.1635 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-05-27-17-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Pitch Diameter 1.155 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-05-27-17-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Pitch Diameter 1.1590 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-05-27-17-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Measurement Average 2.9 mils

Test

DIME Test ID: 2026-05-27-17-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Measurement Average 4.5 mils

Test

DIME Test ID: 2026-05-27-17-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Measurement Average 4 mils

Test

DIME Test ID: 2026-05-27-17-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Hardness Reading Scale C Scale
Hardness Reading Average 32.4
Spacing Ok

Test

DIME Test ID: 2026-05-27-17-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Hardness Reading Scale C Scale
Hardness Reading Average 32.1
Spacing Ok

Test

DIME Test ID: 2026-05-27-17-9
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000316786
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1.25 in
Bolt Length 3.25 in
Hardness Reading Scale C Scale
Hardness Reading Average 31
Spacing Ok

Test

DIME Test ID: 2026-05-27-17-10
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 3
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AW0003167861.2512878000000000A325Atlas
1BW0003167861.2513253000000000A325Atlas
1CW0003167861.2513128000000000A325Atlas
UTM NA
Temperature 0 f