Sample Record for 2026-05-27-15
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001197 DEA: 07319604 EFIS: 0716000025
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-1,101-21.3/21.9,R34.9/R36.1
Work Description: REMOVE AND CONSTRUCT BRIDGE.
Location Description: VENTURA COUNTY ON ROUTE 1 FROM 1.8 MILES NORTH OF ROUTE 1/33 SEPARATION TO 2.0 MILES SOUTH OF A LEASE CANYON ROAD AND ON ROUTE 101 FROM 0.4 MILE NORTH OF DULAH ROAD UNDERCROSSING TO SAN MIGUELITO ROAD UNDERCROSSING
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 BRISTOL STREET, SUITE D204, COSTA MESA, CA 92626
Resident Engineer: Ranjit Singh Structure Rep.: Aziz Maghsoudloo
Sample Information
DIME Sample ID: 2026-05-27-15
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/28/2026
The quantity of what the sample constitutes: 810
A brief description of the sample: A325 Bolt
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AFC Industries
Material Information
Rocap Number(s): NA
Heat Number(s): 10923590
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: A325
Bolt Length(s): 3
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 1-1/4
Bolt Mfg. Lot Number: E424S1
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA
Washer Inner Diameter(s): NA
Test Results
Test
DIME Test ID: 2026-05-27-15-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/02/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E424S1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
3 in
|
|
Pitch Diameter
|
1.1620 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-05-27-15-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/02/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E424S1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
3 in
|
|
Pitch Diameter
|
1.160 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-05-27-15-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/02/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E424S1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
3 in
|
|
Pitch Diameter
|
1.158 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-05-27-15-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/02/2026
Date Tested: 06/02/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E424S1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
3 in
|
|
Measurement Average
|
2.5 mils
|
Test
DIME Test ID: 2026-05-27-15-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/02/2026
Date Tested: 06/02/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E424S1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
3 in
|
|
Measurement Average
|
3.1 mils
|
Test
DIME Test ID: 2026-05-27-15-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/02/2026
Date Tested: 06/02/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E424S1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
3 in
|
|
Measurement Average
|
2.2 mils
|
Test
DIME Test ID: 2026-05-27-15-7
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 06/02/2026
Date Tested: 06/02/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
2
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | E424S1 | 1.25 | 130140 | 0000 | 0000 | A325 | Kleinfelder | | 1B | E424S1 | 1.25 | 130800 | 0000 | 0000 | A325 | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|