Project Information

Project ID: 1002012 DEA: 034J4304 EFIS: 0323000146 QA Service Level: 1
DIST-CO-RTE-PM: 03-UNKNOWN--
Work Description: Building Construction
Location Description: KYBURZ MAINTENANCE STATION AT 13561 HIGHWAY 50
Contractor Name: Dawood Kavosh
Contractor Address: 2002 Elijah St, Fairfield2002 Elijah St, Fairfield, CA 94533, CA 94533
Resident Engineer: Spencer Adams Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-04-29-67
TL Number from the TL Form: 115102
Sample Submitted By Organization: CT SC - 3665 - Shingle Springs
Sample Organization Contact: (530) 821-8266
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/01/2026
The quantity of what the sample constitutes: 12 Cylinders
A brief description of the sample: 4x8 Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Kyburz Maintenance Station Structural Slab
The fabricator/manufacturer/facility name: Sierra Tahoe Ready Mix

Material Information

The concrete mix design number: D673A
The truck number from where the sample was collected: 9
The batch plant ticket number from where the sample was collected: 96428
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: Structural Slab
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-04-29-67-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/28/2026
Date Tested: 05/01/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test: Tested by D10 - Cherokee Lab
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 1130 psi
Maximum load on cylinder 1 14170 lb
Maximum load on cylinder 2 14040 lb
Maximum load on cylinder 3 14440 lb
Compressive strength of cylinder 1 1130.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 1120.0 psi
Compressive strength of cylinder 3 1150 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 2 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-04-29-67-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/28/2026
Date Tested: 05/05/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test: Tested by D10 - Cherokee Lab
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 2230 psi
Maximum load on cylinder 1 29330 lb
Maximum load on cylinder 2 28380 lb
Maximum load on cylinder 3 26960 lb
Compressive strength of cylinder 1 2320.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 2240.0 psi
Compressive strength of cylinder 3 2130 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 6 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-04-29-67-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/28/2026
Date Tested: 05/13/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test: Tested by D10 - Cherokee Lab
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.03 in
Average diameter of cylinder 3 4.02 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.76 in^2
Cross sectional area of cylinder 3 12.69 in^2
Compressive strength (to nearest 10 psi) 3600 psi
Maximum load on cylinder 1 45900 lb
Maximum load on cylinder 2 45980 lb
Maximum load on cylinder 3 45320 lb
Compressive strength of cylinder 1 3620.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3600.0 psi
Compressive strength of cylinder 3 3570 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-04-29-67-4
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/28/2026
Date Tested: 05/27/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test: Tested by D10 - Cherokee Lab
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 4970 psi
Maximum load on cylinder 1 64340 lb
Maximum load on cylinder 2 62780 lb
Maximum load on cylinder 3 61440 lb
Compressive strength of cylinder 1 5090.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4970.0 psi
Compressive strength of cylinder 3 4860 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen no data0 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-04-29-67-5
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 05/28/2026
Date Tested: 04/29/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air Content 5.6 %

Test

DIME Test ID: 2026-04-29-67-6
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 05/28/2026
Date Tested: 04/29/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4.25 inch