Print Report | Back to Sample Detail

Sample Record for 2024-11-07-83

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66665 DEA: BMD EFIS: BMD QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Balanced Mix Design (BMD) data for hot mix asphalt. UCPRC is collecting BMD data from the test track built for accelerated pavement testing
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-11-07-83
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Informational
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/08/2024
The quantity of what the sample constitutes: 48 Boxes
A brief description of the sample: BMD TT2- 0.75 SP +1.25% AC Surface 25% RAP 58-22
From where was the sample collected: Source
Laboratory sample identification: 025-003
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: George Reed - Clements Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 0
Sublot number: 0
HMA Mix Number: 025003
Binder content (%): 5.8
Virgin binder PG: PG 64-16
Design binder PG: PG 58-22
Binder Supplier: Valero Benicia
RAP content (%): 25
WMA Additives: No
Antistrip type: No

Test Results

Test

DIME Test ID: 2024-11-07-83-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/16/2026
Date Tested: 11/07/2025
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.554
Specific Gravity for Sample 2 2.561
Average Specific Gravity 2.557
Theoretical maximum density at 25°C (77°F) 159.2 lb/ft^3

Test

DIME Test ID: 2024-11-07-83-2
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Verified Date: 06/16/2026
Date Tested: 02/12/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used None
Mid term aging protocol None
Test temperature 25 C
Condition method Condition Chamber
Specimen air voids 7 %
Specimen thickness 62 mm
Specimen diameter 150 mm
Displacement 4 mm
Peak load 11.5 kN
Absolute value of the post-peak slope 1570327 N/m
Failure energy 10279 Joules/m^2
Work of failure 95.6 Joules
Cracking tolerance index 317.1
Specimen air voids 2 6.8 %
Specimen thickness 2 61.9 mm
Specimen diameter 2 150 mm
Displacement 2 3.2 mm
Peak load 2 11.4 kN
Absolute value of the post-peak slope 2 1460368 N/m
Failure energy 2 9709 Joules/m^2
Work of failure 2 90.3 Joules
Cracking tolerance index 2 274.7
Specimen air voids 3 7.3 %
Specimen thickness 3 62 mm
Specimen diameter 3 150 mm
Displacement 3 4.2 mm
Peak load 3 10.6 kN
Absolute value of the post-peak slope 3 1683043 N/m
Failure energy 3 9102 Joules/m^2
Work of failure 3 84.7 Joules
Cracking tolerance index 3 254.6
Specimen air voids 4 7 %
Specimen thickness 4 61.9 mm
Specimen diameter 4 150 mm
Displacement 4 4.5 mm
Peak load 4 12.4 kN
Absolute value of the post-peak slope 4 1552484 N/m
Failure energy 4 10881 Joules/m^2
Work of failure 4 101.2 Joules
Cracking tolerance index 4 329.9
Specimen air voids 5 6.9 %
Specimen thickness 5 61.9 mm
Specimen diameter 5 150 mm
Displacement 5 3.9 mm
Peak load 5 12.5 kN
Absolute value of the post-peak slope 5 2073564 N/m
Failure energy 5 10132 Joules/m^2
Work of failure 5 94.2 Joules
Cracking tolerance index 5 215.3

Test

DIME Test ID: 2024-11-07-83-3
Test Method: ASTM D8360-22: Standard Test Method for Determination of Rutting Tolerance Index of Asphalt Mixture Using the Ideal Rutting Test (Rutting Tolerance)
Verified Date: 06/16/2026
Date Tested: 02/25/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation Method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used None
Condition Method Water Bath
Conditioning temperature 50 °C
Specimen Compaction Method SGC
Specimen air voids 7.2 %
Specimen air voids 2 7.4 %
Specimen air voids 3 7.2 %
Specimen air voids 4 7.3 %
Specimen air voids 5 7.2 %
Specimen thickness 0.062 m
Specimen thickness 2 0.0619 m
Specimen thickness 3 0.0619 m
Specimen thickness 4 0.0619 m
Specimen thickness 5 0.062 m
Specimen diameter 0.15 m
Specimen diameter 2 0.15 m
Specimen diameter 3 0.15 m
Specimen diameter 4 0.15 m
Specimen diameter 5 0.15 m
Peak load 2695.6 N
Peak load 2 2695.6 N
Peak load 3 2691.2 N
Peak load 4 2838 N
Peak load 5 2686.7 N
Shear strength 810364 Pa
Shear strength 2 811674 Pa
Shear strength 3 810349 Pa
Shear strength 4 854552 Pa
Shear strength 5 807689 Pa
Rutting tolerance index 53.6
Rutting tolerance index 2 53.7
Rutting tolerance index 3 53.6
Rutting tolerance index 4 56.6
Rutting tolerance index 5 53.5
Average rutting tolerance index 54.2

Test

DIME Test ID: 2024-11-07-83-4
Test Method: CTM 321-0: New Test Method for Determination of Rutting Resistance Using High Temperature Indirect Tensile (HT-IDT) Strength of Asphalt Mixtures
Verified Date: 06/16/2026
Date Tested: 03/04/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used None
Condition Method water bath
Condition temperature 50 C
Condition time 120 min
Specimen air void 6.6 %
Specimen thickness 62 mm
Specimen diameter 150 mm
Testing temperature 50 C
Loading rate 50 mm/min
Maximum load 2090.7 N
Specimen air void 2 7.5 %
Specimen thickness 2 62 mm
Specimen diameter 2 150 mm
Testing temperature 2 50 C
Loading rate 2 50 mm/min
Maximum load 2 1708.1 N
Indirect tensile strength 2 116.9 kPa
Specimen air void 3 7.1 %
Specimen thickness 3 62 mm
Specimen diameter 3 150 mm
Testing temperature 3 50 C
Loading rate 3 50 mm/min
Maximum load 3 2037.3 N
Indirect tensile strength 3 139.5 kPa
Specimen air void 4 7.3 %
Specimen thickness 4 62 mm
Specimen diameter 4 150 mm
Testing temperature 4 50 C
Loading rate 4 50 mm/min
Maximum load 4 1859.4 N
Indirect tensile strength 4 127.3 kPa
Specimen air void 5 6.8 %
Specimen thickness 5 61.9 mm
Specimen diameter 5 150 mm
Testing temperature 5 50 C
Loading rate 5 50 mm/min
Maximum load 5 2166.3 N
Indirect tensile strength 5 148.5 kPa
Average Indirect tensile strength 135.1 kPa

Test

DIME Test ID: 2024-11-07-83-5
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/16/2026
Date Tested: 11/20/2025
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Material was MTOA Aged
Test Result Compliance:
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? SI Units
Mass Determination Water
Specific Gravity for Sample 1 2.564
Specific Gravity for Sample 2 2.567
Average Specific Gravity 2.566
Theoretical maximum density at 25°C (77°F) 77 kg/m^3

Test

DIME Test ID: 2024-11-07-83-6
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Verified Date: 06/16/2026
Date Tested: 02/27/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Material was MTOA Aged
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used CT 320 Reheat 2 hours at compaction temperature
Mid term aging protocol CT 320 20 hours at 100C
Test temperature 25 C
Condition method Condition Chamber
Specimen air voids 7.1 %
Specimen thickness 61.9 mm
Specimen diameter 150 mm
Displacement 72.6 mm
Peak load 8.5 kN
Absolute value of the post-peak slope 1621293 N/m
Failure energy 4846 Joules/m^2
Work of failure 45.1 Joules
Cracking tolerance index 96
Specimen air voids 2 6.8 %
Specimen thickness 2 62 mm
Specimen diameter 2 150 mm
Displacement 2 98.8 mm
Peak load 2 13.8 kN
Absolute value of the post-peak slope 2 1990281 N/m
Failure energy 2 11312 Joules/m^2
Work of failure 2 105.2 Joules
Cracking tolerance index 2 243.1
Specimen air voids 3 7.2 %
Specimen thickness 3 62 mm
Specimen diameter 3 150 mm
Displacement 3 88.2 mm
Peak load 3 14.5 kN
Absolute value of the post-peak slope 3 2139681 N/m
Failure energy 3 11740 Joules/m^2
Work of failure 3 109.2 Joules
Cracking tolerance index 3 217
Specimen air voids 4 6.6 %
Specimen thickness 4 61.9 mm
Specimen diameter 4 150 mm
Displacement 4 113.2 mm
Peak load 4 13.5 kN
Absolute value of the post-peak slope 4 2457246 N/m
Failure energy 4 11423 Joules/m^2
Work of failure 4 106.2 Joules
Cracking tolerance index 4 199.1
Specimen air voids 5 7.1 %
Specimen thickness 5 62 mm
Specimen diameter 5 150 mm
Displacement 5 106.7 mm
Peak load 5 13.4 kN
Absolute value of the post-peak slope 5 2056783 N/m
Failure energy 5 10478 Joules/m^2
Work of failure 5 97.4 Joules
Cracking tolerance index 5 226.7

Test

DIME Test ID: 2024-11-07-83-7
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 06/16/2026
Date Tested: 02/12/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 121 psi
Average Wet Tensile Strength 124 psi
Tensile Strength Ratio 1.02

Test

DIME Test ID: 2024-11-07-83-8
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 06/16/2026
Date Tested: 03/24/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specimen Preparation Method PMLC
Test Temperature 122 F
Air Void Content for specimen A-1 7.3 %
Air Void Content for specimen A-2 6.9 %
Air Void Content for specimen B-1 7.2 %
Air Void Content for specimen B-2 7.1 %
Stripping Inflection Point (Wheel A) no data
Stripping Inflection Point (Wheel B) no data
Maximum impression at 5000 passes (left wheel) 4.45 mm
Maximum impression at 5000 passes (right wheel) 3.44 mm
Average impression at 5000 passes (left/right avg) 3.95 mm
Maximum impression at 10000 passes (left wheel) 5.24 mm
Maximum impression at 10000 passes (right wheel) 4.19 mm
Average impression at 10000 passes (left/right avg) 4.72 mm
Maximum impression at 15000 passes (left wheel) 5.74 mm
Maximum impression at 15000 passes (right wheel) 4.67 mm
Average impression at 15000 passes (left/right avg) 5.21 mm
Maximum impression at 20000 passes (left wheel) 6.08 mm
Maximum impression at 20000 passes (right wheel) 5.14 mm
Average impression at 20000 passes (left/right avg) 5.61 mm
Average impression at 25000 passes (left/right avg) no data