Print Report | Back to Sample Detail

Sample Record for 2024-11-06-103

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66665 DEA: BMD EFIS: BMD QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Balanced Mix Design (BMD) data for hot mix asphalt. UCPRC is collecting BMD data from the test track built for accelerated pavement testing
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-11-06-103
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Informational
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/06/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/08/2024
The quantity of what the sample constitutes: 48 Boxes
A brief description of the sample: BMD TT1- 0.75 SP Surface 25% RAP 58-22
From where was the sample collected: Source
Laboratory sample identification: 025-004
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: George Reed - Clements Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 0
Sublot number: 0
HMA Mix Number: 025004
Binder content (%): 4.5
Virgin binder PG: PG 64-16
Design binder PG: PG 58-22
Binder Supplier: Valero Benicia
RAP content (%): 25
WMA Additives: No
Antistrip type: No

Test Results

Test

DIME Test ID: 2024-11-06-103-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/04/2026
Date Tested: 11/05/2025
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Method Performed Mechanical Agitation - Method A
Mass of oven-dry sample in air for Sample 1 2611.2 grams
Mass of sample in water for Sample 1 1609.8 grams
Mass of oven-dry sample in air for Sample 2 2609.7 grams
Mass of sample in water for Sample 2 1605.6 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.608
Specific Gravity for Sample 2 2.599
Average Specific Gravity 2.604
Theoretical maximum density at 25°C (77°F) 162.1 lb/ft^3

Test

DIME Test ID: 2024-11-06-103-2
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Verified Date: 06/04/2026
Date Tested: 04/29/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used None
Mid term aging protocol None
Test temperature 25 C
Condition method Condition Chamber
Specimen air voids 7 %
Specimen thickness 62 mm
Specimen diameter 150 mm
Displacement 72.2 mm
Peak load 15.8 kN
Absolute value of the post-peak slope 2865934 N/m
Failure energy 9272 Joules/m^2
Work of failure 86.2 Joules
Cracking tolerance index 104.7
Specimen air voids 2 7 %
Specimen thickness 2 62 mm
Specimen diameter 2 150 mm
Displacement 2 71 mm
Peak load 2 16.5 kN
Absolute value of the post-peak slope 2 3388590 N/m
Failure energy 2 10157 Joules/m^2
Work of failure 2 94.5 Joules
Cracking tolerance index 2 94.9
Specimen air voids 3 6.6 %
Specimen thickness 3 62 mm
Specimen diameter 3 150 mm
Displacement 3 65.8 mm
Peak load 3 17.5 kN
Absolute value of the post-peak slope 3 3909074 N/m
Failure energy 3 9397 Joules/m^2
Work of failure 3 87.4 Joules
Cracking tolerance index 3 66.2
Specimen air voids 4 6.6 %
Specimen thickness 4 62 mm
Specimen diameter 4 150 mm
Displacement 4 65.5 mm
Peak load 4 17.5 kN
Absolute value of the post-peak slope 4 4116698 N/m
Failure energy 4 8837 Joules/m^2
Work of failure 4 82.2 Joules
Cracking tolerance index 4 58.6
Specimen air voids 5 6.6 %
Specimen thickness 5 62 mm
Specimen diameter 5 150 mm
Displacement 5 73.7 mm
Peak load 5 18 kN
Absolute value of the post-peak slope 5 4238389 N/m
Failure energy 5 9565 Joules/m^2
Work of failure 5 89 Joules
Cracking tolerance index 5 68.5

Test

DIME Test ID: 2024-11-06-103-3
Test Method: CTM 321-0: New Test Method for Determination of Rutting Resistance Using High Temperature Indirect Tensile (HT-IDT) Strength of Asphalt Mixtures
Verified Date: 06/04/2026
Date Tested: 04/29/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used None
Condition Method water bath
Condition temperature 50 C
Condition time 120 min
Specimen air void 6.5 %
Specimen thickness 62 mm
Specimen diameter 150 mm
Testing temperature 50 C
Loading rate 50 mm/min
Maximum load 3238.3 N
Specimen air void 2 6.8 %
Specimen thickness 2 62 mm
Specimen diameter 2 150 mm
Testing temperature 2 50 C
Loading rate 2 50 mm/min
Maximum load 2 3073.7 N
Indirect tensile strength 2 210.4 kPa
Specimen air void 3 6.8 %
Specimen thickness 3 62 mm
Specimen diameter 3 150 mm
Testing temperature 3 50 C
Loading rate 3 50 mm/min
Maximum load 3 3411.8 N
Indirect tensile strength 3 233.6 kPa
Specimen air void 4 7.1 %
Specimen thickness 4 62 mm
Specimen diameter 4 150 mm
Testing temperature 4 50 C
Loading rate 4 50 mm/min
Maximum load 4 3171.6 N
Indirect tensile strength 4 217.1 kPa
Specimen air void 5 6.6 %
Specimen thickness 5 62 mm
Specimen diameter 5 150 mm
Testing temperature 5 50 C
Loading rate 5 50 mm/min
Maximum load 5 3171.6 N
Indirect tensile strength 5 217.1 kPa
Average Indirect tensile strength 220.0 kPa

Test

DIME Test ID: 2024-11-06-103-4
Test Method: ASTM D8360-22: Standard Test Method for Determination of Rutting Tolerance Index of Asphalt Mixture Using the Ideal Rutting Test (Rutting Tolerance)
Verified Date: 06/04/2026
Date Tested: 04/29/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation Method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used None
Condition Method Water Bath
Conditioning temperature 50 °C
Specimen Compaction Method SGC
Specimen air voids 6.5 %
Specimen air voids 2 6.7 %
Specimen air voids 3 6.8 %
Specimen air voids 4 7 %
Specimen air voids 5 6.9 %
Specimen thickness 0.062 m
Specimen thickness 2 0.062 m
Specimen thickness 3 0.062 m
Specimen thickness 4 0.062 m
Specimen thickness 5 0.062 m
Specimen diameter 0.15 m
Specimen diameter 2 0.15 m
Specimen diameter 3 0.15 m
Specimen diameter 4 0.15 m
Specimen diameter 5 0.15 m
Peak load 5431.3 N
Peak load 2 5182.2 N
Peak load 3 5751.5 N
Peak load 4 4942 N
Peak load 5 5048.7 N
Shear strength 1632784 Pa
Shear strength 2 1557898 Pa
Shear strength 3 1729044 Pa
Shear strength 4 1485688 Pa
Shear strength 5 1517765 Pa
Rutting tolerance index 108.1
Rutting tolerance index 2 103.1
Rutting tolerance index 3 114.4
Rutting tolerance index 4 98.3
Rutting tolerance index 5 100.4
Average rutting tolerance index 104.9

Test

DIME Test ID: 2024-11-06-103-5
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/04/2026
Date Tested: 11/19/2025
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Material was MTOA Aged
Test Result Compliance:
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.606
Specific Gravity for Sample 2 2.607
Average Specific Gravity 2.606
Theoretical maximum density at 25°C (77°F) 162.2 lb/ft^3

Test

DIME Test ID: 2024-11-06-103-6
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Verified Date: 06/04/2026
Date Tested: 04/30/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 5
Specimen Preparation method PMLC
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Specimen Number no data
Reheat protocol used CT 320 Reheat 2 hours at compaction temperature
Mid term aging protocol CT 320 20 hours at 100C
Test temperature 25 C
Condition method Condition Chamber
Specimen air voids 6.8 %
Specimen thickness 62 mm
Specimen diameter 150 mm
Displacement 59.6 mm
Peak load 21.3 kN
Absolute value of the post-peak slope 5949283 N/m
Failure energy 9435 Joules/m^2
Work of failure 87.7 Joules
Cracking tolerance index 37.9
Specimen air voids 2 7.1 %
Specimen thickness 2 62 mm
Specimen diameter 2 150 mm
Displacement 2 71.1 mm
Peak load 2 20 kN
Absolute value of the post-peak slope 2 5124245 N/m
Failure energy 2 10886 Joules/m^2
Work of failure 2 101.2 Joules
Cracking tolerance index 2 61
Specimen air voids 3 6.6 %
Specimen thickness 3 62 mm
Specimen diameter 3 150 mm
Displacement 3 65 mm
Peak load 3 19.4 kN
Absolute value of the post-peak slope 3 4743872 N/m
Failure energy 3 9322 Joules/m^2
Work of failure 3 86.7 Joules
Cracking tolerance index 3 53.7
Specimen air voids 4 6.8 %
Specimen thickness 4 62 mm
Specimen diameter 4 150 mm
Displacement 4 63.1 mm
Peak load 4 20.6 kN
Absolute value of the post-peak slope 4 5595336 N/m
Failure energy 4 10746 Joules/m^2
Work of failure 4 99.9 Joules
Cracking tolerance index 4 48.9
Specimen air voids 5 6.7 %
Specimen thickness 5 62 mm
Specimen diameter 5 150 mm
Displacement 5 62.1 mm
Peak load 5 20.7 kN
Absolute value of the post-peak slope 5 5584632 N/m
Failure energy 5 9288 Joules/m^2
Work of failure 5 86.4 Joules
Cracking tolerance index 5 41.3

Test

DIME Test ID: 2024-11-06-103-7
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 06/04/2026
Date Tested: 05/01/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 163 psi
Average Wet Tensile Strength 144 psi
Tensile Strength Ratio 0.88

Test

DIME Test ID: 2024-11-06-103-8
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 06/04/2026
Date Tested: 05/11/2026
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specimen Preparation Method PMLC
Test Temperature 122 F
Air Void Content for specimen A-1 7.2 %
Air Void Content for specimen A-2 6.8 %
Air Void Content for specimen B-1 7.4 %
Air Void Content for specimen B-2 6.7 %
Stripping Inflection Point (Wheel A) 0
Stripping Inflection Point (Wheel B) 0
Maximum impression at 5000 passes (left wheel) 1.89 mm
Maximum impression at 5000 passes (right wheel) 2.02 mm
Average impression at 5000 passes (left/right avg) 1.96 mm
Maximum impression at 10000 passes (left wheel) 2.44 mm
Maximum impression at 10000 passes (right wheel) 2.65 mm
Average impression at 10000 passes (left/right avg) 2.55 mm
Maximum impression at 15000 passes (left wheel) 2.8 mm
Maximum impression at 15000 passes (right wheel) 3.11 mm
Average impression at 15000 passes (left/right avg) 2.96 mm
Maximum impression at 20000 passes (left wheel) 3.03 mm
Maximum impression at 20000 passes (right wheel) 3.43 mm
Average impression at 20000 passes (left/right avg) 3.23 mm
Average impression at 25000 passes (left/right avg) no data