Project Information

Project ID: 1001361 DEA: 120M9704 EFIS: 1213000099 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-57-11.5/12.5
Work Description: CONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: Unknown
Resident Engineer: Aythem Al-Saleh Structure Rep.: Mohammad Rousta

Sample Information

DIME Sample ID: 2026-05-22-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 05/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/28/2026
The quantity of what the sample constitutes: 3122 120 T Heads
A brief description of the sample: ASMT A706 #5 rebar w/ 120 T heads
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HRC - Fountain Valley, CA

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 137526
Head Manufacturer Lot Number(s): 100013306040
Rebar Size: #5
Headed Bar Model Name: HRC 120
Size of Head: Full Size - 9x
Head Connection Type:
Head Shape: Square
Rebar Manufacturer: Cascade Steel Rolling Mills - Oregon
Head Manufacturer: Nucor Cold Finish Utah
Head Fabricator: HRC Fountain Valley CA
Material Standard Code: ASTM A706
Headed Bar Unique ID: 9FW-17-03

Test Results

Test

DIME Test ID: 2026-05-22-2-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 06/02/2026
Date Tested: 06/02/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 20
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.312813090500Ok NeckingKleinfelder
10.312747088500Ok NeckingKleinfelder
10.312965095500Ok NeckingKleinfelder
10.312746088500Ok NeckingKleinfelder
60.312826091000Ok NeckingKleinfelder
60.312781089500Ok NeckingKleinfelder
60.312846092000Ok NeckingKleinfelder
60.312865092500Ok NeckingKleinfelder
110.312868092500Ok NeckingKleinfelder
110.312868092500Ok NeckingKleinfelder
110.312850092000Ok NeckingKleinfelder
110.312865092500Ok NeckingKleinfelder
160.312866092500Ok NeckingKleinfelder
160.312860092500Ok NeckingKleinfelder
160.312806090500Ok NeckingKleinfelder
160.312882093000Ok NeckingKleinfelder
210.312835091500Ok NeckingKleinfelder
210.312810090500Ok NeckingKleinfelder
210.312828091000Broke at HeadKleinfelder
210.312856092000Ok NeckingKleinfelder
Temperature 0 f
UTM NA