Project Information

Project ID: 1002051 DEA: 120T4604 EFIS: 1222000053 QA Service Level: 1
DIST-CO-RTE-PM: 12---unknown
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-04-23-61
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/23/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/24/2026
The quantity of what the sample constitutes: 6
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 26-0079
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

The concrete mix design number: 5264125A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2019726
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: SB Rte 55 Edinger Ave Off Ramp Propane Pad
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-04-23-61-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/21/2026
Date Tested: 05/07/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.5 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4790 psi
Maximum load on cylinder 1 61090 lb
Maximum load on cylinder 2 60270 lb
Maximum load on cylinder 3 58940 lb
Compressive strength of cylinder 1 4860.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4821.6 psi
Compressive strength of cylinder 3 4688.9 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test

DIME Test ID: 2026-04-23-61-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/21/2026
Date Tested: 05/21/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 3.98 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.44 in^2
Cross sectional area of cylinder 2 12.5 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5240 psi
Maximum load on cylinder 1 65290 lb
Maximum load on cylinder 2 62740 lb
Maximum load on cylinder 3 68410 lb
Compressive strength of cylinder 1 5248.4 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 5019.2 psi
Compressive strength of cylinder 3 5442.3 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours