Print Report | Back to Sample Detail

Sample Record for 2026-05-20-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994675 DEA: 07390204 EFIS: 0722000334 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47-0.4 / 2.1
Work Description: Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location Description: RTE 47 between Terminal Island and San Pedro PM 0.4/2.1
Contractor Name: Skanska
Contractor Address: 1995 Agua Mansa Rd, Riverside, CA 92509
Resident Engineer: Sam Gallardo Structure Rep.: Sami Deeb

Sample Information

DIME Sample ID: 2026-05-20-47
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/20/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/21/2026
The quantity of what the sample constitutes: 6 - 4x8 concrete cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Fabricator
Laboratory sample identification: 1088-224
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coreslab Strcutures

Material Information

The concrete mix design number: 2556-TB-Type III only
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 105012
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SCC- Light weight concrete
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-05-20-47-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/03/2026
Date Tested: 06/03/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 5080 psi
Maximum load on cylinder 1 65380 lb
Maximum load on cylinder 2 64130 lb
Maximum load on cylinder 3 62950 lb
Compressive strength of cylinder 1 5180.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 5080.0 psi
Compressive strength of cylinder 3 4980 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-05-20-47-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/17/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 4.02 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.69 in^2
Compressive strength (to nearest 10 psi) 5420 psi
Maximum load on cylinder 1 66260 lb
Maximum load on cylinder 2 71570 lb
Maximum load on cylinder 3 68480 lb
Compressive strength of cylinder 1 5220.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 5640.0 psi
Compressive strength of cylinder 3 5400 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data