Print Report | Back to Sample Detail

Sample Record for 2026-05-18-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez

Sample Information

DIME Sample ID: 2026-05-18-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: JMFR
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Corona

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 49R003ARSPW
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier: Valero
RAP content (%): 0
WMA Additives: No
Antistrip type:

Test Results

Test

DIME Test ID: 2026-05-18-21-1
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 06/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Core 6B25 is 99.5%> 97%, does not comply.
Test Result Compliance: does not comply
Additional Comments When Verified:
Number of Cores 3
Core ID 6A25
Dry Weight 1066.6 grams
Parrafin Coated Weight 1083.4 grams
Coated Weight in Water 594.5 grams
Theoretical Maximum Density 2.438
Core 2 ID 6B25
Dry Weight 2 1124.6 grams
Parrafin Coated Weight 2 1141.5 grams
Coated Weight in Water 2 659.4 grams
Core 3 ID 6C25
Dry Weight 3 1156.2 grams
Parrafin Coated Weight 3 1172.2 grams
Coated Weight in Water 3 645.1 grams

Test

DIME Test ID: 2026-05-18-21-2
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 06/01/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 3
Core ID 6A26
Dry Weight 1123.7 grams
Parrafin Coated Weight 1141.3 grams
Coated Weight in Water 625.9 grams
Theoretical Maximum Density 2.438
Core 2 ID 6B26
Dry Weight 2 1106.7 grams
Parrafin Coated Weight 2 1123.3 grams
Coated Weight in Water 2 614.8 grams
Core 3 ID 6C26
Dry Weight 3 1091.7 grams
Parrafin Coated Weight 3 1111 grams
Coated Weight in Water 3 607.9 grams

Test

DIME Test ID: 2026-05-18-21-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/29/2026
Date Tested: 05/28/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7149.5 grams
Mass of oven-dry sample in air for Sample 1 2517.4 grams
Mass of container filled with the sample and water for Sample 1 8634.5 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.438
Theoretical maximum density at 25°C (77°F) 2430.9 kg/m^3

Test

DIME Test ID: 2026-05-18-21-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/29/2026
Date Tested: 05/28/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 7.5% Tested 7.89%, Complies, oven # 1
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4041.8 g
Mass of the specimen and specimen basket assembly prior to ignition 6110.8 g
Mass of HMA Sample prior to ignition 2069 g
Corrected Asphalt Binder Content 7.89 %
Mass Loss 173 g
Mass of aggregate remaining after ignition 1896 g
Correction Factor (Percent by mass of HMA Specimen) 0.47 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C