Print Report | Back to Sample Detail

Sample Record for 2026-05-01-53

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000710 DEA: 100P9244 EFIS: 1023000226 QA Service Level: 1
DIST-CO-RTE-PM: 10-MPA-140-42.0/42.7
Work Description: Fergusen Slide Rock Avalanche Shed
Location Description: Mariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
Contractor Name: Myers and Sons Construction, LLC/Ralph L. Wadsworth
Contractor Address: 2554 Millcreek Drive, Sacramento, CA 95833
Resident Engineer: Jonathan Ngai Structure Rep.: Natasha Collins

Sample Information

DIME Sample ID: 2026-05-01-53
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 05/01/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/18/2026
The quantity of what the sample constitutes: 4
A brief description of the sample: #9 HRC 500/510 Coupler
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HRC

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 80
Rebar Manufacturer: Nucor
Coupler Manufacturer: HRC
Intermediate Assembler or Fabricator:
Rebar Size: #9
Coupler Model: HRC 500/510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 74141308, 73141712
Rebar Heat Number(s): 3500043534
Rebar Size 2 :
Coupler Unique ID: TP-17-03

Test Results

Test

DIME Test ID: 2026-05-01-53-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/25/2026
Date Tested: 06/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1191.000.0119114470114470Uniform Elongation 5 39 percentBroke at RebarAtlas
2191.000115850115850Uniform Elongation 5 15 percentBroke at RebarAtlas
3191.000115210115210Uniform Elongation 5 40 percentBroke at RebarAtlas
4191.000114490114490Uniform Elongation 4 89 percentBroke at RebarAtlas
Temperature 0 f
UTM NA
Halo ID NA

Test

DIME Test ID: 2026-05-01-53-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/25/2026
Date Tested: 06/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11910121550121600Uniform Elongation Pass Control BarAtlas
Temperature 0 f
UTM NA
Halo ID NA