Project Information

Project ID: 1001927 DEA: 070Y2204 EFIS: 0724000151 QA Service Level: 1
DIST-CO-RTE-PM: 07---unknown
Work Description:
Location Description: In VENTURA COUNTY FROM ABOUT 6.2 MILES NORTH OF OJAI FROM SOUTH OF MATILIJA TUNNEL TO 0.3 MILE SOUTH OF BEAR CREEK
Contractor Name: Nationwide Shotcrete
Contractor Address: 23638 lyons avenue, Newhall, CA, 91321
Resident Engineer: Justin Saeidian Structure Rep.: Hussam Buran

Sample Information

DIME Sample ID: 2026-05-07-49
TL Number from the TL Form: 5072026
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 05/07/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/12/2026
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 26-131
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nationwide Shotcrete

Material Information

The concrete mix design number: XX 5000 3/8" SC SF
The truck number from where the sample was collected: 100064145
The batch plant ticket number from where the sample was collected: 32E07
Concrete batch plant: Cemex
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Coring Nozzle
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-05-07-49-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/15/2026
Date Tested: 05/14/2026
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 3.99 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.5 in^2
Compressive strength (to nearest 10 psi) 4950 psi
Maximum load on cylinder 1 63522 lb
Maximum load on cylinder 2 63228 lb
Maximum load on cylinder 3 60919 lb
Compressive strength of cylinder 1 5005.7 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4982.5 psi
Compressive strength of cylinder 3 4873.5 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours