Print Report | Back to Sample Detail

Sample Record for 2026-05-14-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001361 DEA: 120M9704 EFIS: 1213000099 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-57-11.5/12.5
Work Description: CONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: Unknown
Resident Engineer: Aythem Al-Saleh Structure Rep.: Mohammad Rousta

Sample Information

DIME Sample ID: 2026-05-14-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 05/14/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/20/2026
The quantity of what the sample constitutes: 374 hoops
A brief description of the sample: #8 rebar x 7'-0" hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RKR Steel Welding

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 052326
Hoop Manufacturer Lot Number(s): Lots 1 thru 3
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #8
Diameter of Hoop: 7'-0"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade steel
Welding Company: RKR Steel Welding
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test

DIME Test ID: 2026-05-14-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 05/28/2026
Date Tested: 05/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 8
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1180.797831099000ok neckingKleinfelder
2180.797735098000ok neckingKleinfelder
3180.797733098000ok neckingKleinfelder
4180.797501095000broke at weldKleinfelder
1380.797513095000ok neckingKleinfelder
2380.796415081000ok neckingKleinfelder
3380.797514095000ok neckingKleinfelder
4380.797442094000ok neckingKleinfelder
UTM NA
Temperature 0 f