Print Report | Back to Sample Detail

Sample Record for 2018-02-01-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211070 DEA: 080Q3004 EFIS: 0800020191 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-138-R17.1/R19.2
Work Description: REALIGN SECTION OF STATE ROUTE 138
Location Description: Near Hesperia from 1.9 mi East of Route 15 to 0.1 mi West of Summit Post Office Road to realign sections of State Route 138
Contractor Name: Skanska Civil USA
Contractor Address: 1995 Agua Mansa Road, Riverside, CA 92509
Resident Engineer: Amgad Benjamin Structure Rep.: Tim Flores

Sample Information

DIME Sample ID: 2018-02-01-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Sample Organization Contact: (562) 500-5861
Type of Sample: Authorization
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 02/01/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/05/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: No 5 Epoxy Rebar
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coating

Material Information

Rebar Heat Number(s): PL17210111
Rebar Epoxy Batch Number(s): TJ77002NA
Rebar Coating Specification: ASTM A775
Rebar Size (#): 5
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coating
Rebar Powder Manufacturer: AkzoNobel Surface Chemistry, LLC
Release Number: Unknown
Quality Assurance Code: C172083

Test Results

Test

DIME Test ID: 2018-02-01-1-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 02/06/2018
Date Tested: 02/05/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 9.99
Second Bar Mean 9.14
Lower spec. limit LSL 7
Upper spec. limit USL 12
Bar # for First Bar no data
Bar # for Second Bar no data
Total mean value 9.57
Total number of values less than LSL no data
Total number of values greater than USL no data

Test

DIME Test ID: 2018-02-01-1-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 02/06/2018
Date Tested: 02/05/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday no data0
Total Length 2.6
Holidays Per Linear Foot of Bar no data0 holiday per ft
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass