Print Report | Back to Sample Detail

Sample Record for 2026-04-02-98

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 44444 DEA: ASCP EFIS: ASCP QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-04-02-98
TL Number from the TL Form:
Sample Submitted By Organization: Albina Asphalt - Klamath Falls
Sample Organization Contact: (503) 539-3830
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 04/02/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/02/2026
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Tank 18
From where was the sample collected: Manufacturer
Laboratory sample identification: PG64284226KF18
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Klamath Falls, OR

Material Information

Performance Grade: PG 64-28
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Albina Asphalt
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test

DIME Test ID: 2026-04-02-98-1
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test no data
Test Temperature no data
Speed no data
Spindle size no data
Torque no data
Viscosity reading #1 (A) no data
Viscosity reading #2 (B) no data
Viscosity reading #3 (C) no data
Average viscosity 0.458 Pa-s

Test

DIME Test ID: 2026-04-02-98-2
Test Method: AASHTO T48-20: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg) Celsius and mmHg
Corrected Flash Point no data

Test

DIME Test ID: 2026-04-02-98-3
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) no data
Ductility of sample 80 cm

Test

DIME Test ID: 2026-04-02-98-4
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase Original binder
Phase Angle (δ) (for the 10 cycles) no data
Dynamic Shear, G*/sin(δ) 1.20 kPa

Test

DIME Test ID: 2026-04-02-98-5
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers? One
Is mass change correction factor needed? no data

Test

DIME Test ID: 2026-04-02-98-6
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase RTFO residue
Phase Angle (δ) (for the 10 cycles) no data
Dynamic Shear, G*/sin(δ) 3.72 kPa

Test

DIME Test ID: 2026-04-02-98-7
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter no data
Phase Angle (δ) (for the 10 cycles) no data
(G*) x sin(δ)= 1588 kPa

Test

DIME Test ID: 2026-04-02-98-8
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Maximum test bath temperature at 240 S no data
Minimum test bath temperature at 240 S no data
Estimated Stiffness Modulus 8.0 s no data
Estimated m-value 8.0 s no data
Estimated Stiffness Modulus 15.0 s no data
Estimated m-value 15.0 s no data
Estimated Stiffness Modulus 30.0 s no data
Estimated m-value 30.0 s no data
Estimated Stiffness Modulus 60.0 s 171.000 MPa
Estimated m-value 60.0 s no data
Estimated Stiffness Modulus 120.0 s no data
Estimated m-value 120.0 s no data
Estimated Stiffness Modulus 240.0 s no data
Estimated m-value 240.0 s no data

Test

DIME Test ID: 2026-04-02-98-9
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 05/12/2026
Date Tested: 05/12/2026
Submitted By Organization: Albina Asphalt - Klamath Falls
Organization Address: 801 Main Street,
Organization City: Vancouver
Organization State: WA
Organization Zipcode: 98686
Organization Email: keven.heitschmidt@albina.com
Organization Phone: (503) 539-3830
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Maximum test bath temperature at 240 S no data
Minimum test bath temperature at 240 S no data
Estimated Stiffness Modulus 8.0 s no data
Estimated m-value 8.0 s no data
Estimated Stiffness Modulus 15.0 s no data
Estimated m-value 15.0 s no data
Estimated Stiffness Modulus 30.0 s no data
Estimated m-value 30.0 s no data
Estimated Stiffness Modulus 60.0 s no data
Estimated m-value 60.0 s 0.317
Estimated Stiffness Modulus 120.0 s no data
Estimated m-value 120.0 s no data
Estimated Stiffness Modulus 240.0 s no data
Estimated m-value 240.0 s no data