Print Report | Back to Sample Detail

Sample Record for 2026-05-10-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez

Sample Information

DIME Sample ID: 2026-05-10-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/10/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: JMFR
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Corona

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 49R003ARSPW
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier: Valero
RAP content (%): 0
WMA Additives: No
Antistrip type:

Test Results

Test

DIME Test ID: 2026-05-10-6-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/19/2026
Date Tested: 05/14/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2550.7 grams
Mass of container filled with the sample and water for Sample 1 8969 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.412
Theoretical maximum density at 25°C (77°F) 2405 kg/m^3

Test

DIME Test ID: 2026-05-10-6-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/19/2026
Date Tested: 05/14/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Oven 3, complies
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4041.5 g
Mass of the specimen and specimen basket assembly prior to ignition 6091.4 g
Mass of HMA Sample prior to ignition 2049.9 g
Corrected Asphalt Binder Content 7.83 %
Mass Loss 172.5 g
Mass of aggregate remaining after ignition 1877.4 g
Correction Factor (Percent by mass of HMA Specimen) 0.59 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test

DIME Test ID: 2026-05-10-6-3
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 05/19/2026
Date Tested: 05/13/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 3
Core ID GA 15
Dry Weight 1142.2 grams
Parrafin Coated Weight 1162.4 grams
Coated Weight in Water 638.9 grams
Theoretical Maximum Density 2.412
Core 2 ID GB 15
Dry Weight 2 1173.4 grams
Parrafin Coated Weight 2 1195.5 grams
Coated Weight in Water 2 657.5 grams
Core 3 ID GC 15
Dry Weight 3 1328.9 grams
Parrafin Coated Weight 3 1352.5 grams
Coated Weight in Water 3 745.8 grams

Test

DIME Test ID: 2026-05-10-6-4
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 05/19/2026
Date Tested: 05/13/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 3
Core ID GA 16
Dry Weight 1114.2 grams
Parrafin Coated Weight 1137.2 grams
Coated Weight in Water 623.7 grams
Theoretical Maximum Density 2.412
Core 2 ID GB 16
Dry Weight 2 1249.9 grams
Parrafin Coated Weight 2 1273.7 grams
Coated Weight in Water 2 690.1 grams
Core 3 ID GC 16
Dry Weight 3 1250.3 grams
Parrafin Coated Weight 3 1272.5 grams
Coated Weight in Water 3 690.6 grams

Test

DIME Test ID: 2026-05-10-6-5
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 07/01/2026
Date Tested: 05/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm Tested an Avg of 3.70 mm
Test Result Compliance: complies
Additional Comments When Verified:
Specimen Preparation Method PMLC
Test Temperature 122 F
Air Void Content for specimen A-1 6.3 %
Air Void Content for specimen A-2 6.3 %
Air Void Content for specimen B-1 6.4 %
Air Void Content for specimen B-2 6.6 %
Stripping Inflection Point (Wheel A) >15000
Stripping Inflection Point (Wheel B) >15000
Maximum impression at 5000 passes (left wheel) 1.26 mm
Maximum impression at 5000 passes (right wheel) 1.29 mm
Average impression at 5000 passes (left/right avg) 1.27 mm
Maximum impression at 10000 passes (left wheel) 2.47 mm
Maximum impression at 10000 passes (right wheel) 2.51 mm
Average impression at 10000 passes (left/right avg) 2.49 mm
Maximum impression at 15000 passes (left wheel) 3.66 mm
Maximum impression at 15000 passes (right wheel) 3.73 mm
Average impression at 15000 passes (left/right avg) 3.7 mm
Average impression at 20000 passes (left/right avg) no data
Average impression at 25000 passes (left/right avg) no data