Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001245 DEA: 040AA624 EFIS: 0419000518
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-1-0.9/5.8
Work Description: COLD PLANE AC PVMT, HMA (TYPE A) AND INDIVIDUAL SLAB REPLACEMENT.
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO FROM HOLLOWAY AVENUE TO CALIFORNIA STREET
Contractor Name: GRANITE ROCK COMPANY
Contractor Address: Unknown
Resident Engineer: Charles koos Structure Rep.: Chetan Sihra
DIME Sample ID: 2026-04-25-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/25/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/27/2026
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2 HMA + 15% RAP
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Peninsula Road Materials-RC
DIME Test ID: 2026-04-25-6-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/30/2026
Date Tested: 04/29/2026
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL. 4
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3547.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5052.8 g
|
|
Mass of HMA Sample prior to ignition
|
1505 g
|
|
Corrected Asphalt Binder Content
|
5.36 %
|
|
Mass Loss
|
98.1 g
|
|
Mass of aggregate remaining after ignition
|
1406.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.96 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.2 %
|
|
Test Temperature
|
482 C
|
DIME Test ID: 2026-04-25-6-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/30/2026
Date Tested: 04/29/2026
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL. 5
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2914.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4431.7 g
|
|
Mass of HMA Sample prior to ignition
|
1517.6 g
|
|
Corrected Asphalt Binder Content
|
5.19 %
|
|
Mass Loss
|
96.4 g
|
|
Mass of aggregate remaining after ignition
|
1421.2 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.96 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.2 %
|
|
Test Temperature
|
482 C
|
DIME Test ID: 2026-04-25-6-3
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 05/01/2026
Date Tested: 04/30/2026
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL. 4
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
-1.1 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
0.9 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
1.3 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
1.1 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
0.1 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.2 %
|
DIME Test ID: 2026-04-25-6-4
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 05/01/2026
Date Tested: 04/30/2026
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL. 5
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
-1.1 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
0.9 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
1.3 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
1.1 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
0.1 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.2 %
|
DIME Test ID: 2026-04-25-6-5
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/01/2026
Date Tested: 04/30/2026
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL. 6
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3547.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5066.7 g
|
|
Corrected Asphalt Binder Content
|
5.32 %
|
|
Mass of HMA Sample prior to ignition
|
1519.4 g
|
|
Mass Loss
|
98.4 g
|
|
Mass of aggregate remaining after ignition
|
1421 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.96 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.2 %
|
|
Test Temperature
|
482 C
|
DIME Test ID: 2026-04-25-6-6
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 05/04/2026
Date Tested: 05/01/2026
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL. 6
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
-1.1 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
0.9 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
1.3 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
1.1 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
0.1 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.2 %
|