Print Report | Back to Sample Detail

Sample Record for 2026-04-29-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001329 DEA: 100X7404 EFIS: 1013000008 QA Service Level: 1
DIST-CO-RTE-PM: 10-CAL-12-17.1/17.5
Work Description: BRIDGE REPLACEMENT.
Location Description: CALAVERAS COUNTY NEAR SAN ANDREAS FROM 0.2 MILE WEST OF NORTH FORK CALAVERAS RIVER BRIDGE TO 0.2 MILE EAST OF NORTH CALAVERAS RIVER BRIDGE
Contractor Name: STEELHEAD CONSTRUCTORS JV
Contractor Address: 2940 INNSBRUCK DR, REDDING, CA, 96003
Resident Engineer: Elaine Yip Structure Rep.: Ron Matin

Sample Information

DIME Sample ID: 2026-04-29-11
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California Corporation - Lathrop
Sample Organization Contact: (209) 249-4700
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 04/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/29/2026
The quantity of what the sample constitutes: 1 cubic foot
A brief description of the sample: 1 cubic foot
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ConFab Lathrop

Material Information

The concrete mix design number: L_95M1L_KRC38_PF1
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 14178
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bed 4, 1st Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-04-29-11-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 04/30/2026
Date Tested: 04/29/2026
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 76 F

Test

DIME Test ID: 2026-04-29-11-2
Test Method: ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating Concrete
Verified Date: 04/30/2026
Date Tested: 04/29/2026
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What unit system is used for measurements? inches
Slump Flow 21 in
Filling the mold procedure Filling Procedure B (Inverted Mold)
Diameter 1 21 in
Diameter 2 21 in
Visual Stability Index no data0

Test

DIME Test ID: 2026-04-29-11-3
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 04/30/2026
Date Tested: 04/29/2026
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air content 1.5 %

Test

DIME Test ID: 2026-04-29-11-4
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/30/2026
Date Tested: 04/30/2026
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 8.27 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 69233 in^2
Cross sectional area of cylinder 2 72791 in^2
Cross sectional area of cylinder 3 71423 in^2
Compressive strength (to nearest 10 psi) 5660 psi
Maximum load on cylinder 1 69233 lb
Maximum load on cylinder 2 72791 lb
Maximum load on cylinder 3 71423 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 1 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data