Sample Record for 2026-04-18-22

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995228 DEA: 07347904 EFIS: 0718000123 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-31.2/41.4
Work Description: COLD PLANE, PLACE HMA, RHMA, JPCP, ISR, & REPLACE BRIDGE SLABS.
Location Description: LOS ANGELES FROM WILSHIRE BOULEVARD UNDERCROSSING TO VICTORY BOULEVARD UNDERCROSSING
Contractor Name: RASMUSSEN/VANGUARD
Contractor Address: 28548 Livingston Ave, Valencia , CA,91355-4171
Resident Engineer: Ridwan Salman Structure Rep.: Gon Choi

Sample Information

DIME Sample ID: 2026-04-18-22
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Sample Organization Contact: (909) 833-5780
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2026
The quantity of what the sample constitutes: 10 CY of 650 CY
A brief description of the sample: LCB-RSC
From where was the sample collected: Job Site
Laboratory sample identification: 26-1350
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard Construction Mobile Batch Plant

Material Information

The concrete mix design number: HE4X4BM
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-04-18-22-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/28/2026
Date Tested: 04/25/2026
Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Organization Address: 620 South Magnolia Avenue, Building G,
Organization City: Ontario
Organization State: CA
Organization Zipcode: 91762
Organization Email: mdorsch@kleinfelder.com
Organization Phone: (909) 833-5780
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 7600 psi
Maximum load on cylinder 1 211118 lb
Maximum load on cylinder 2 218023 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours