Sample Record for 2026-04-15-49
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001902 DEA: 061H6704 EFIS: 0625000240
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-190-26.65
Work Description: Replace exiting bridge rail on EB direction of SR 190, demo and reconstruct overhang, remove existing AC overlay, deck overhang strengthening at bridge rail, poly conc overlay, install new ST-75 barrier rail.
Location Description: Tule River Bridge (BR #46-0187).
Contractor Name: Chapco Construction (Matthew Clifford)
Contractor Address: 6000 Mortono Street, Sacramento, CA 95828
Resident Engineer: Cesar Mandujano Structure Rep.: Ye Yang
Sample Information
DIME Sample ID: 2026-04-15-49
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/24/2026
The quantity of what the sample constitutes: 6
A brief description of the sample: 7/8" x 18" F1554 Grade 105 Rod
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Atwater Metal Fabrication
Material Information
Rocap Number(s): n/a
Heat Number(s): 79007441 Bolt
1000133404 Nut
190156048 Washer
Nut Mfg. Lot Number(s): W000317446
Washer Mfg. Lot Number(s): 0925-789
Bolt Specification: F1554 Grade 105
Bolt Length(s): 18"
Nut Specification: A563 Grade DH
Washer Specification: F436 Type 1
Finish: HDG
Diameter/Size: 7/8"
Bolt Mfg. Lot Number: 7900744101
Rocap Test Requirement(s): 0
Lubricant Requirements(s): 0
Washer Inner Diameter(s): 0
Test Results
Test
DIME Test ID: 2026-04-15-49-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
79007441
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
RED
|
|
Size
|
0.875 in
|
|
Bolt Length
|
18 in
|
|
Pitch Diameter
|
0.8054 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-04-15-49-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
79007441
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
RED
|
|
Size
|
0.875 in
|
|
Bolt Length
|
18 in
|
|
Measurement Average
|
6.3 mils
|
Test
DIME Test ID: 2026-04-15-49-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000317446
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.9 mils
|
Test
DIME Test ID: 2026-04-15-49-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
0925-789
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.4 mils
|
Test
DIME Test ID: 2026-04-15-49-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
0925-789
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
38
|
|
Spacing
|
Ok
|
Test
DIME Test ID: 2026-04-15-49-6
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | 79007441 | 0.875 | 64075 | 0 | 0 | F1554 | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
Test
DIME Test ID: 2026-04-15-49-7
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 06/02/2026
Date Tested: 05/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | W000317446 | 0.875 | 69300 | 0 | 0 | Nut Proof Load | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|