Sample Record for 2026-04-27-5
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001625 DEA: 11173704 EFIS: 1100020255
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-2.6/3.2
Work Description: WIDEN INTERCHANGE, STRUCTURES, HMA-A, RHMA-G, LANDSCAPE, & ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF PALM AVENUE OVERCROSSING
Contractor Name: SEMA CONSTRUCTION
Contractor Address: 1901 Cmino Vida Roble, Suite 100, Carlsbad, CA 92008
Resident Engineer: Karl Hartline Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2026-04-27-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 04/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/29/2026
The quantity of what the sample constitutes: 140 hoops
A brief description of the sample: #6 rebar 2'-6" hoop
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RKR Steel Welding
Material Information
Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 4100000898
Hoop Manufacturer Lot Number(s): #1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 2'-6"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: RKR Steel Welding
Coating Standards: Uncoated
Weld Type: Flash Welded
Test Results
Test
DIME Test ID: 2026-04-27-5-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 05/07/2026
Date Tested: 05/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 6 | 0.44 | 41590 | 94500 | ok necking | Kleinfelder | | 2 | 1 | 6 | 0.44 | 41240 | 93500 | ok necking | Kleinfelder | | 3 | 1 | 6 | 0.44 | 41020 | 93000 | ok necking | Kleinfelder | | 4 | 1 | 6 | 0.44 | 40180 | 91500 | ok necking | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|