Print Report | Back to Sample Detail

Sample Record for 2026-04-24-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001108 DEA: 061A0904 EFIS: 0620000065 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-168-49.1/49.5
Work Description: SHAVER LAKE VIADUCT. CONSTRUCT SIDEHILL VIADUCT STRUCTURE.
Location Description: FRESNO COUNTY NEAR SHAVER LAKE FROM 1.3 MILES EAST OF DALTON AVENUE TO 0.2 MILE WEST OF HUNTINGTON LAKE ROAD.
Contractor Name: Viking Construction Company, Inc. (Zander Newman)
Contractor Address: 3835 security park drive, Rancho Cordova, CA 95742
Resident Engineer: Mohammed Alqutami Structure Rep.: Martin Garcia

Sample Information

DIME Sample ID: 2026-04-24-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 04/24/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/30/2026
The quantity of what the sample constitutes: 16
A brief description of the sample: #8x 4'-7", ASTM A706 Gr. 60
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar Cascade

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1202071900
Hoop Manufacturer Lot Number(s): 1, 5, 10, 15
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #8
Diameter of Hoop: 4'-7"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade Steel
Welding Company: TNT Rebar Company
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test

DIME Test ID: 2026-04-24-8-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 05/14/2026
Date Tested: 05/14/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 16
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1180.796733085000ok neckingKleinfelder
2180.796666084500ok neckingKleinfelder
3180.796614083500ok neckingKleinfelder
4180.796646084000ok neckingKleinfelder
1580.796650084000ok neckingKleinfelder
2580.796569083000ok neckingKleinfelder
3580.796489082000ok neckingKleinfelder
4580.796569083000ok neckingKleinfelder
11080.796508082500ok neckingKleinfelder
21080.796635084000ok neckingKleinfelder
31080.796586083500ok neckingKleinfelder
41080.796593083500ok neckingKleinfelder
11580.797118090000ok neckingKleinfelder
21580.797126090000ok neckingKleinfelder
31580.797115090000ok neckingKleinfelder
41580.797058089500ok neckingKleinfelder
UTM NA
Temperature 0 f