Project Information

Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-0.1/14.6
Work Description: REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE
Location Description: SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Springs, Suite 200 | San Diego, CA 92128, San Diego, CA 92128
Resident Engineer: Jason Alsheikh Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2026-04-24-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 04/24/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/29/2026
The quantity of what the sample constitutes: 434 pcs
A brief description of the sample: #8 rebar 3'-4" hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RKR Steel Welding

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 389925
Hoop Manufacturer Lot Number(s): Lot #1-3
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #8
Diameter of Hoop: 3'-4"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade Steel
Welding Company: RKR Steel Welding
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test

DIME Test ID: 2026-04-24-3-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 05/07/2026
Date Tested: 05/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 8
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1180.797513095000Okay NeckingKleinfelder
2180.797250092000Okay NeckingKleinfelder
3180.797374093500Okay NeckingKleinfelder
4180.797486095000Okay NeckingKleinfelder
1380.796726085000Okay NeckingKleinfelder
2380.796757085500Okay NeckingKleinfelder
3380.796768085500Okay NeckingKleinfelder
4380.796738085500Okay NeckingKleinfelder
UTM NA
Temperature 0 f