Project Information

Project ID: 1000611 DEA: 120R32U4 EFIS: 1222000054 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-55-0.2/R17.8
Work Description: COLD PLANE, PLACE RHMA, REPLACE CB, SIGNS AND MODIFY LIGHTING SYSTEM.
Location Description: ORANGE COUNTY FROM 0.1 MILE SOUTH OF ROUTE 55/1 SEPARATION IN NEWPORT BEACH TO ROUTE 55/91 SEPARATION IN ANAHEIM
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 East Lincoln Avenue, Orange, CA 92865
Resident Engineer: Tyrone Taylor Structure Rep.: Matthew Chang

Sample Information

DIME Sample ID: 2026-04-16-48
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2026
The quantity of what the sample constitutes: 6
A brief description of the sample: RSC Flexural Beams
From where was the sample collected: Job Site
Laboratory sample identification: 26-0068
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Short Load Concrete

Material Information

The concrete mix design number: CTS-65-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: Inside lanes 55 fwy in both NB / SB around Lincoln
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-04-16-48-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 04/23/2026
Date Tested: 04/19/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 3 days
Modulus of rupture 690 psi
Modulus of rupture 2 610 psi
Modulus of rupture average 630 psi
Modulus of rupture 3 590 psi

Test

DIME Test ID: 2026-04-16-48-2
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 04/23/2026
Date Tested: 04/23/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 3 days
Modulus of rupture 630 psi
Modulus of rupture 2 600 psi
Modulus of rupture average 610 psi
Modulus of rupture 3 590 psi