Project Information

Project ID: 1000781 DEA: 040P9304 EFIS: 0418000027 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-80-7.6,12.8
Work Description: BRIDGE RAILING, MVP, CURB & GUTTER, SIDEWALKS, & ELECTRICAL SYSTEMS.
Location Description: CONTRA COSTA COUNTY IN PINOLE AT APPIAN WAY OVERCROSSING AND NEAR HERCULES AT CUMMINGS SKYWAY OVERCROSSING.
Contractor Name: BUGLER CONSTRUCTION, INC.
Contractor Address: 4847 Hopyard Road Ste 4-395, Pleasanton, CA 94588
Resident Engineer: Zhuohang Deng Structure Rep.: Rommoney Wu

Sample Information

DIME Sample ID: 2026-04-17-1
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Richmond
Sample Organization Contact: (510) 231-7108
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/21/2026
The quantity of what the sample constitutes: 58cy
A brief description of the sample: over crossing bridge deck
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1623710
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: f27
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-04-17-1-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/23/2026
Date Tested: 04/23/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3700 psi
Maximum load on cylinder 1 45020 lb
Maximum load on cylinder 2 49265 lb
Maximum load on cylinder 3 47365 lb
Compressive strength of cylinder 1 3580.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 3840.0 psi
Compressive strength of cylinder 3 3690 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 0.98
Correction factor for cylinder 3 0.98
Age of specimen 6 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data