Print Report | Back to Sample Detail

Sample Record for 2026-03-23-65

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000851 DEA: 07351704 EFIS: 0718000204 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-118,118-15.6/R17.9
Work Description: COLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HMA.
Location Description: VENTURA COUNTY IN MOORPARK AT VARIOUS LOCATIONS
Contractor Name: C. A. RASMUSSEN, INC.
Contractor Address: Unknown
Resident Engineer: Pantaleon Rivera Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-03-23-65
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 03/23/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Sun Valley

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test

DIME Test ID: 2026-03-23-65-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 04/17/2026
Date Tested: 04/15/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 61 C
Softening Point Sample 2 61 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test

DIME Test ID: 2026-03-23-65-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 04/17/2026
Date Tested: 04/15/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 37 0.1 mm

Test

DIME Test ID: 2026-03-23-65-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 04/17/2026
Date Tested: 04/15/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 2 mm
Final Dial reading (F1) 60 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F2) 58 mm
Ball Penetration (P3) 2 mm
Final Dial reading (F3) 59 mm
Resilience 1 42 %
Resilience 2 43 %
Resilience 3 43 %
Average Resilience 43 %
Minutes Reaction no data