Print Report | Back to Sample Detail

Sample Record for 2026-04-13-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001469 DEA: 120K62U4 EFIS: 1224000090 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA, -5-R25.8/30.3
Work Description: CONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 16700 Valley View Avenue Suite 300, La Mirada, CA 90638
Resident Engineer: Clay Walker Structure Rep.: Younho Rew

Sample Information

DIME Sample ID: 2026-04-13-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 04/13/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/22/2026
The quantity of what the sample constitutes: 218 pcs
A brief description of the sample: #7 rebar Gr60 A706 6'-6" hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: Bridge
The fabricator/manufacturer/facility name: Martines Steel

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 381924
Hoop Manufacturer Lot Number(s): Lots 1 and 2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #7
Diameter of Hoop: 6'-6"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade Steel
Welding Company: Martinez Steel
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test

DIME Test ID: 2026-04-13-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 04/28/2026
Date Tested: 04/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 8
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1170.605563092500Okay NeckingKleinfelder
2170.605449091000Okay NeckingKleinfelder
3170.605591093000Okay NeckingKleinfelder
4170.605420090500Affected ZoneKleinfelder
1270.605569093000Okay NeckingKleinfelder
2270.605556092500Okay NeckingKleinfelder
3270.605462091000Okay NeckingKleinfelder
4270.605427090500Okay NeckingKleinfelder
UTM NA
Temperature 0 f