Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002080 DEA: 081T4604 EFIS: 0826000072
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-330-34/42
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2026-03-17-44
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 03/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/17/2026
The quantity of what the sample constitutes: 25.5 kg
A brief description of the sample: Native Subgrade
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CTM 231 TEST LOCATION
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SR-330 Upbound, Slope Area of Drainage Pipe @ PM 34.80, 7' Above Drainage Pipe
Where the material sample would have been placed if not sampled:
DIME Test ID: 2026-03-17-44-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 04/09/2026
Date Tested: 03/17/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Standard Count Density
|
1595 g/cc
|
|
Count or Density 1
|
781 g/cc
|
|
Count or Density 2
|
850 g/cc
|
|
Count or Density 3
|
869 g/cc
|
|
Standard Count Moisture
|
656 g/cc
|
|
Moisture Count 1
|
163 g/cc
|
|
Moisture Count 2
|
159 g/cc
|
|
Moisture Count 3
|
149 g/cc
|
|
Sum of Count or Density
|
2500 g/cc
|
|
Average of Count or Density
|
833 g/cc
|
|
Sum of Moisture Count
|
471 g/cc
|
|
Average of Moisture Count
|
157 g/cc
|
|
Count Ratio Density
|
0.52
|
|
Count Ratio Moisture
|
0.24
|
|
Calculated Percent Relative Compaction
|
96 %
|
|
Reported Percent Relative Compaction
|
96 %
|
DIME Test ID: 2026-03-17-44-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 04/09/2026
Date Tested: 03/17/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is oversize material
|
No
|
|
In-place wet density
|
2.17
|
|
Highest adjust wet density
|
2.26
|
|
Relative compaction
|
96
|
|
% Moisture
|
no data
|
|
Optimum Moisture
|
no data
|