Print Report | Back to Sample Detail

Sample Record for 2026-04-06-23

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001940 DEA: 023J52U4 EFIS: 0225000084 QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-36-15.7/16.4
Work Description: Horse Gulch Combined
Location Description:
Contractor Name: JF Shea Constrcution
Contractor Address: 17400 Clear Creek Road, Redding, CA 96001
Resident Engineer: Damion Farley Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-04-06-23
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 04/06/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2026
The quantity of what the sample constitutes: 100lbs of Aggregate
A brief description of the sample: 1"x#4
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JF Shea Construction, Aggregate Products

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-45-0019
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2026-04-06-23-1
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 04/09/2026
Date Tested: 04/07/2026
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent finer than No. 200 sieve 1.3 %

Test 2 of 3

DIME Test ID: 2026-04-06-23-2
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 04/09/2026
Date Tested: 04/07/2026
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content 1.2 %

Test 3 of 3

DIME Test ID: 2026-04-06-23-3
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 04/09/2026
Date Tested: 04/07/2026
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? 1 in. x No. 4 - Coarse Aggregate
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 99 %
Cumulative percent passing the 3/4 in. sieve 84 %
Cumulative percent passing the 1/2 in. sieve 30 %
Cumulative percent passing the 3/8 in. sieve 8 %
Cumulative percent passing the #4 sieve 2 %
Cumulative percent passing the #8 sieve 2 %