Sample Record for 2026-04-09-9
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000103 DEA: 081J8604 EFIS: 0818000123
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10,15,40,58,60,etc.-Var
Work Description: MODIFYING CMS SYSTEMS AND FURNISH SIGN STRUCTURE (VERSATILE TRUSS).
Location Description: SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Lawrance Yaacoub Structure Rep.: Matt Bruce
Sample Information
DIME Sample ID: 2026-04-09-9
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 04/09/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/09/2026
The quantity of what the sample constitutes: 23.7 kg
A brief description of the sample: Class II Aggregate Base
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CTM 231 TEST LOCATION
Material Information
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SR-210 EB, MVP @ PM R0.81, Sta 66+75 - 67+55
Where the material sample would have been placed if not sampled:
Test Results
Test
DIME Test ID: 2026-04-09-9-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 04/09/2026
Date Tested: 04/09/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Standard Count Density
|
1587 g/cc
|
|
Count or Density 1
|
1477 g/cc
|
|
Count or Density 2
|
1519 g/cc
|
|
Count or Density 3
|
1461 g/cc
|
|
Standard Count Moisture
|
651 g/cc
|
|
Moisture Count 1
|
50 g/cc
|
|
Moisture Count 2
|
52 g/cc
|
|
Moisture Count 3
|
50 g/cc
|
|
Sum of Count or Density
|
4457 g/cc
|
|
Average of Count or Density
|
1486 g/cc
|
|
Sum of Moisture Count
|
152 g/cc
|
|
Average of Moisture Count
|
51 g/cc
|
|
Count Ratio Density
|
0.94
|
|
Count Ratio Moisture
|
0.08
|
|
Calculated Percent Relative Compaction
|
95.2 %
|
|
Reported Percent Relative Compaction
|
95 %
|
Test
DIME Test ID: 2026-04-09-9-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 04/09/2026
Date Tested: 04/09/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is oversize material
|
No
|
|
In-place wet density
|
2.17
|
|
Highest adjust wet density
|
2.28
|
|
Relative compaction
|
95
|
|
% Moisture
|
no data
|
|
Optimum Moisture
|
no data
|