Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001197 DEA: 07319604 EFIS: 0716000025
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-1,101-21.3/21.9,R34.9/R36.1
Work Description: REMOVE AND CONSTRUCT BRIDGE.
Location Description: VENTURA COUNTY ON ROUTE 1 FROM 1.8 MILES NORTH OF ROUTE 1/33 SEPARATION TO 2.0 MILES SOUTH OF A LEASE CANYON ROAD AND ON ROUTE 101 FROM 0.4 MILE NORTH OF DULAH ROAD UNDERCROSSING TO SAN MIGUELITO ROAD UNDERCROSSING
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 BRISTOL STREET, SUITE D204, COSTA MESA, CA 92626
Resident Engineer: Ranjit Singh Structure Rep.: Aziz Maghsoudloo
DIME Sample ID: 2026-04-06-16
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 04/06/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/08/2026
The quantity of what the sample constitutes: 1
A brief description of the sample: .6 pc strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire Products Corporation
Comments:
Reel/Coil/Pack Number(s): S337135-6
Number of Coils:
Group Number:
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0517926
Mfg. Lot Number(s): S337135-6
Manufacturer(s): Sumiden Wire Products Corporation
DIME Test ID: 2026-04-06-16-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/19/2026
Date Tested: 04/29/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | | S0517926 | S337135-6 | 0.217 | 61108 | 55023 | 29.3 | 4.1 | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
|
Extensometers
|
NA
|