Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000607 DEA: 081K6904 EFIS: 0819000090
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-5.7/11.8
Work Description: ROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM.
Location Description: RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Joseph Lopez Structure Rep.: Unknown
DIME Sample ID: 2026-01-28-64
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 01/28/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/29/2026
The quantity of what the sample constitutes: kg
A brief description of the sample: Class II Aggregate Base
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CTM 231 Test Locations
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SR-74 WB Mainline, 1.6' BFG, Sta 611+28 - 611+40
Where the material sample would have been placed if not sampled:
DIME Test ID: 2026-01-28-64-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 04/07/2026
Date Tested: 01/29/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Standard Count Density
|
1445 g/cc
|
|
Count or Density 1
|
817 g/cc
|
|
Count or Density 2
|
898 g/cc
|
|
Count or Density 3
|
835 g/cc
|
|
Standard Count Moisture
|
637 g/cc
|
|
Moisture Count 1
|
131 g/cc
|
|
Moisture Count 2
|
121 g/cc
|
|
Moisture Count 3
|
117 g/cc
|
|
Sum of Count or Density
|
2550 g/cc
|
|
Average of Count or Density
|
850 g/cc
|
|
Sum of Moisture Count
|
369 g/cc
|
|
Average of Moisture Count
|
123 g/cc
|
|
Count Ratio Density
|
0.59
|
|
Count Ratio Moisture
|
0.19
|
|
Calculated Percent Relative Compaction
|
96.7 %
|
|
Reported Percent Relative Compaction
|
97 %
|