Print Report | Back to Sample Detail

Sample Record for 2026-03-23-54

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001361 DEA: 120M9704 EFIS: 1213000099 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-57-11.5/12.5
Work Description: CONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: Unknown
Resident Engineer: Aythem Al-Saleh Structure Rep.: Mohammad Rousta

Sample Information

DIME Sample ID: 2026-03-23-54
TL Number from the TL Form:
Sample Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Sample Organization Contact: (951) 396-0214
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 03/23/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/23/2026
The quantity of what the sample constitutes: 9 cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: OLDCASTLE PRECAST

Material Information

The concrete mix design number: UV-247B
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 84964
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: On site next next to the form
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2026-03-23-54-1
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 04/09/2026
Date Tested: 03/23/2026
Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Organization Address: 10650 Hemlock Avenue,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92337
Organization Email: rodger.munoz@oldcastle.com
Organization Phone: (951) 396-0214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 6 inch

Test 2 of 6

DIME Test ID: 2026-03-23-54-2
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Organization Address: 10650 Hemlock Avenue,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92337
Organization Email: rodger.munoz@oldcastle.com
Organization Phone: (951) 396-0214
Data has not been verified.

Test 3 of 6

DIME Test ID: 2026-03-23-54-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Organization Address: 10650 Hemlock Avenue,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92337
Organization Email: rodger.munoz@oldcastle.com
Organization Phone: (951) 396-0214
Data has not been verified.

Test 4 of 6

DIME Test ID: 2026-03-23-54-4
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Organization Address: 10650 Hemlock Avenue,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92337
Organization Email: rodger.munoz@oldcastle.com
Organization Phone: (951) 396-0214
Data has not been verified.

Test 5 of 6

DIME Test ID: 2026-03-23-54-5
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/09/2026
Date Tested: 03/23/2026
Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Organization Address: 10650 Hemlock Avenue,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92337
Organization Email: rodger.munoz@oldcastle.com
Organization Phone: (951) 396-0214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 0.04 in
Average diameter of cylinder 2 0.04 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 3 0.04 in
Cross sectional area of cylinder 1 4 in^2
Cross sectional area of cylinder 2 4 in^2
Cross sectional area of cylinder 3 4 in^2
Compressive strength (to nearest 10 psi) 10 psi
Maximum load on cylinder 1 37 lb
Maximum load on cylinder 2 37 lb
Maximum load on cylinder 3 37 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 6 of 6

DIME Test ID: 2026-03-23-54-6
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 04/14/2026
Date Tested: 03/23/2026
Submitted By Organization: OldCastle Precast, Incorporated - Fontana
Organization Address: 10650 Hemlock Avenue,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92337
Organization Email: rodger.munoz@oldcastle.com
Organization Phone: (951) 396-0214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 84 F