Print Report | Back to Sample Detail

Sample Record for 2026-03-30-30

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001439 DEA: 061A7604 EFIS: 0621000015 COOP: NONE QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-46-51.4/R57.9
Work Description: COLD PLANE AC PAVEMENT, RHMA OVERLAY, CONC. BARRIER AND RUMBLE STRIPS.
Location Description: KERN COUNTY IN AND NEAR WASCO FROM 0.20 MILE EAST OF ROUTE 43 TO 0.30 MILE EAST OF ROUTE 46/99 SEPARATION
Contractor Name: Granite Construction
Contractor Address: 3005 James Road, Bakersfield, CA 93308
Resident Engineer: Alejandro Ruezga Structure Rep.: Ivan Cruz

Sample Information

DIME Sample ID: 2026-03-30-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 03/30/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/01/2026
The quantity of what the sample constitutes: 12 concrete cylinders 4X8
A brief description of the sample: structural concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Golden empire Wasco

Material Information

The concrete mix design number: NCT09013
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-03-30-30-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/06/2026
Date Tested: 04/06/2026
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 2660 psi
Maximum load on cylinder 1 31670 lb
Maximum load on cylinder 2 34720 lb
Maximum load on cylinder 3 33970 lb
Compressive strength of cylinder 1 2519.5 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 2762.1 psi
Compressive strength of cylinder 3 2702.5 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours