Print Report | Back to Sample Detail

Sample Record for 2026-03-16-62

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000851 DEA: 07351704 EFIS: 0718000204 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-118,118-15.6/R17.9
Work Description: COLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HMA.
Location Description: VENTURA COUNTY IN MOORPARK AT VARIOUS LOCATIONS
Contractor Name: C. A. RASMUSSEN, INC.
Contractor Address: Unknown
Resident Engineer: Pantaleon Rivera Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-03-16-62
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 03/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/23/2026
The quantity of what the sample constitutes: 4 bags comb aggs, 2 bags RAP
A brief description of the sample: PSUE 3/4" WMA A SP R25
From where was the sample collected: Manufacturer
Laboratory sample identification: 0158A-28
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ingevity/SJR/Fish Canyon Irwindale/ Vulcan Sun Valley

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Belt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: 220200WW SVA SJR
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test

DIME Test ID: 2026-03-16-62-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 05/12/2026
Date Tested: 03/24/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: combined virgin aggregate gradation
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 96 %
Cumulative percent passing the 1/2 in. sieve 66 %
Cumulative percent passing the 3/8 in. sieve 51 %
Cumulative percent passing the #4 sieve 36.3 %
Cumulative percent passing the #8 sieve 26 %
Cumulative percent passing the #16 sieve 16 %
Cumulative percent passing the #30 sieve 10 %
Cumulative percent passing the #50 sieve 5 %
Cumulative percent passing the #100 sieve 3 %
Cumulative percent passing the #200 sieve 1.9 %

Test

DIME Test ID: 2026-03-16-62-2
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 05/12/2026
Date Tested: 04/07/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.636
Bulk specific gravity (SSD Basis) 2.674
Apparent specific gravity 2.740
Absorption 1.4 %

Test

DIME Test ID: 2026-03-16-62-3
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 05/12/2026
Date Tested: 03/25/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk SSD
Specific Gravity 2.686
Absorption 0.8 %

Test

DIME Test ID: 2026-03-16-62-4
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 05/12/2026
Date Tested: 03/27/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 3964 grams
Percent loss after 100 revolutions 4 %
Percent loss after 500 revolutions 21 %

Test

DIME Test ID: 2026-03-16-62-5
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 05/12/2026
Date Tested: 03/26/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 70

Test

DIME Test ID: 2026-03-16-62-6
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 05/12/2026
Date Tested: 03/27/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Percentage of fractured, coarse, 2 faced particles tested 100 %
Percentage of fractured, coarse, 1 faced particles tested 100 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test

DIME Test ID: 2026-03-16-62-7
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 05/12/2026
Date Tested: 03/27/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.636
Average uncompacted voids 45.7 %

Test

DIME Test ID: 2026-03-16-62-8
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 05/12/2026
Date Tested: 03/26/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method B
Determination By Mass
Dimensional ratio used 5:1
Weighted percentage of particles (by mass) that were flat and elongated 1 %
Weighted percentage of particles (by mass) that were not flat and elongated 99 %