Sample Record for 2026-03-19-35
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995493 DEA: 081G6704 EFIS: 0816000049
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-79-5.4/11.4
Work Description: HOT MIX ASPHALT, SOIL NAIL, STRUCTURAL CONCRETE AND ROADWAY EXC.
Location Description: RIVERSIDE COUNTY NEAR TEMECULA FROM 0.4 MILE SOUTH OF SAGE ROAD TO 1.1 MILES SOUTH OF PAUBA ROAD
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 CUSHING STE 200, IRVINE, CA 92618
Resident Engineer: Osama Abdalla Structure Rep.: Arnel Vega
Sample Information
DIME Sample ID: 2026-03-19-35
TL Number from the TL Form: 1085-711
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/19/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/20/2026
The quantity of what the sample constitutes: 8
A brief description of the sample: 4x8
From where was the sample collected: Job Site
Laboratory sample identification: 1085-711
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: np
Material Information
The concrete mix design number: 5236125A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: na
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW343 Stem
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2026-03-19-35-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 03/30/2026
Date Tested: 03/26/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
3510 psi
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Compressive strength of cylinder 1
|
3557.7 psi
|
|
Compressive strength of cylinder 2
|
3467.3 psi
|
|
Maximum load on cylinder 1
|
44720 lb
|
|
Maximum load on cylinder 2
|
44000 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
7 days
|
Test
DIME Test ID: 2026-03-19-35-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 04/02/2026
Date Tested: 04/02/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
4090 psi
|
|
Average diameter of cylinder 1
|
3.99 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Compressive strength of cylinder 1
|
4196.0 psi
|
|
Compressive strength of cylinder 2
|
3992.8 psi
|
|
Maximum load on cylinder 1
|
52450 lb
|
|
Maximum load on cylinder 2
|
50190 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
14 days
|
Test
DIME Test ID: 2026-03-19-35-3
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 04/16/2026
Date Tested: 04/16/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.5 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
5040 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
3.99 in
|
|
Compressive strength of cylinder 1
|
4963.6 psi
|
|
Compressive strength of cylinder 2
|
5114.4 psi
|
|
Maximum load on cylinder 1
|
62690 lb
|
|
Maximum load on cylinder 2
|
63930 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
28 days
|