Print Report | Back to Sample Detail

Sample Record for 2026-03-17-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001645 DEA: 051R1004 EFIS: 0523000125 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO, -1-32.6
Work Description: BRIDGE REPLACEMENT, HMA, AND RSP PROTECTION.
Location Description: SAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE
Contractor Name: SOUZA CONSTRUCTION
Contractor Address: 4027 Santa Fe Road, San Luis Obispo, CA 93403
Resident Engineer: Rick Silva Structure Rep.: Dave Luis

Sample Information

DIME Sample ID: 2026-03-17-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Control
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 03/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/20/2026
The quantity of what the sample constitutes: 1
A brief description of the sample: 7 Wire steel stressing strand
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments:
Reel/Coil/Pack Number(s): T350346-9
Number of Coils:
Group Number:
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): T1378378
Mfg. Lot Number(s): N/A
Manufacturer(s): Sumiden Wire

Test Results

Test

DIME Test ID: 2026-03-17-4-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 04/21/2026
Date Tested: 04/20/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test: Elongation Passed
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
T1378378T350346-90.217597705412027.30000Atlas
UTM NA
Temperature 0 f
Extensometers NA