Print Report | Back to Sample Detail

Sample Record for 2026-03-16-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001575 DEA: 061H9604 EFIS: 0625000104 QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-46,119-VAR
Work Description: COLD PLANE AC PAVEMENT AND PLACING RHMA TYPE G.
Location Description: KERN COUNTY AT VARIOUS LOCATIONS
Contractor Name: Griffith Company (Edward Torres)
Contractor Address: 1128 Carrier Parkway Avenue, Bakersfield, CA 93308
Resident Engineer: Alejandro Ruezga Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-03-16-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/16/2026
The quantity of what the sample constitutes: L2SL3- 12 box HMA, 2 bags of cold feed,
A brief description of the sample: 1/2" HMA- Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Griffith Edmonston

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 2
Sublot number: 3
HMA Mix Number:
Binder content (%): 4.9
Virgin binder PG: PG 70-10
Design binder PG: PG 70-10
Binder Supplier: San Juaquin Refinery
RAP content (%): 15
WMA Additives: Yes
Antistrip type: LIme 0.8%

Test Results

Test

DIME Test ID: 2026-03-16-19-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road, Suite 100,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: 661-549-8281
This test has been superseded on 03/18/2026. The corrected test ID is: 2026-03-16-19-2
Reason: retested

Test

DIME Test ID: 2026-03-16-19-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/18/2026
Date Tested: 03/17/2026
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
The test was superseded from test ID: 2026-03-16-19-1
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of the specimen basket assembly 4321 g
Mass of the specimen and specimen basket assembly prior to ignition 5890.9 g
Mass of HMA Sample prior to ignition 1569.9 g
Corrected Asphalt Binder Content 4.74 %
Mass Loss 82.9 g
Mass of aggregate remaining after ignition 1487 g
Correction Factor (Percent by mass of HMA Specimen) 0.54 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 F