Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993812 DEA: 11431274 EFIS: 1121000129
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R0.3/R36.0
Work Description: CMGC Project- Restore the pavement to a state of good repair through roadway rehabilitation, pavement preservation, drainage restoration, transportation management system upgrades, and American with Disabilities Act (ADA) infrastructure improvements.
Location Description: SD County
Contractor Name: Kiewit Infrastrucure
Contractor Address: West 2200 Columbia House Boulevard, Vancouver, WA 98661
Resident Engineer: Timothy Poppe Structure Rep.: Unknown
DIME Sample ID: 2026-03-15-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/15/2026
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: Daily Production
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Lakeside
DIME Test ID: 2026-03-15-2-1
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 03/27/2026
Date Tested: 03/27/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: cOMPLIES
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Cores
|
2
|
|
Core 1 ID
|
2 A 6
|
|
Dry Weight 1
|
549.8 grams
|
|
Parrafin Coated Weight 1
|
562.5 grams
|
|
Coated Weight in Water 1
|
305.4 grams
|
|
Theoretical Maximum Density
|
2.42
|
|
Core 2 ID
|
2 B 6
|
|
Dry Weight 2
|
912.7 grams
|
|
Parrafin Coated Weight 2
|
923.2 grams
|
|
Coated Weight in Water 2
|
509.2 grams
|
|
Sublot Relative Compaction
|
93.7 %
|
DIME Test ID: 2026-03-15-2-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/26/2026
Date Tested: 03/16/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 7.50 % Tested 7.78 %
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3920.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5472.1 g
|
|
Mass of HMA Sample prior to ignition
|
1551.4 g
|
|
Corrected Asphalt Binder Content
|
7.78 %
|
|
Mass Loss
|
122.2 g
|
|
Mass of aggregate remaining after ignition
|
1429.2 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.1 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-03-15-2-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/26/2026
Date Tested: 03/16/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 2.460 Tested 2 Times 1st- 2.419 2nd - 2.420
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1543.2 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8381.2 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.42
|
|
Theoretical maximum density at 25°C (77°F)
|
150.6 lb/ft^3
|