Print Report | Back to Sample Detail

Sample Record for 2026-03-13-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001248 DEA: 120K93U4 EFIS: 1224000084 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-57,91-13.9/16.1,4.8/6.6
Work Description: CONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location Description: ANAHEIM AND PLACENTIA ON ROUTE 57 FROM WAGNER AVENUE OVERCROSSING TO 0.2 MILE NORTH OF MIRALOMA AVENUE OVERCROSSING AND ON ROUTE 91 FROM 0.1 MILE EAST OF ACACIA STREET UNDERCROSSING TO 0.2 MILE EAST OF LA PALMA AVENUE OVERCROSSING
Contractor Name: OHLA USA, INC
Contractor Address: 2550 East Miraloma Way, Suite 200, Anaheim, CA 92806
Resident Engineer: Charlie Nakamoto Structure Rep.: Tien Chu

Sample Information

DIME Sample ID: 2026-03-13-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 03/13/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/24/2026
The quantity of what the sample constitutes: 20 Strand Packs
A brief description of the sample: 1/2" Uncoated Seven Wire Steel Strand for Prestressed Concrete
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pinnacle Prestress, Inc.

Material Information

Comments:
Reel/Coil/Pack Number(s): S133462-7, S133463-6, S133463-8, S133464-6, S133465-6, S133465-7, S133465-8, S133462-1, S133463-7, S133464-2, S133464-3, S133464-7, S133464-8, S133465-1, S133462-2, S133462-3, S133462-4, S133463-1, S133463-2, S133463-3
Number of Coils: 20
Group Number:
Strand Diameter: .5 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0546825
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire Products Corporation

Test Results

Test

DIME Test ID: 2026-03-13-6-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 04/06/2026
Date Tested: 04/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 20
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0546825S133464-80.153424864107129.34.86Kleinfelder
S0546825S133462-20.153428994086628.35.11Kleinfelder
S0546825S133464-60.153430924124029.13.87Kleinfelder
S0546825S133463-70.153437214104229.43.71Kleinfelder
S0546825S133465-70.153436384132029.13.96Kleinfelder
S0546825S133465-60.153417874098828.94.11Kleinfelder
S0546825S133463-80.153439914052428.64.21Kleinfelder
S0546825S133464-20.153426124088529.33.56Kleinfelder
S0546825S133462-70.153419193833329.23.85Kleinfelder
S0546825S133465-10.153439594106628.64.48Kleinfelder
S0546825S133463-30.153418114082028.74.48Kleinfelder
S0546825S133463-20.153433034109828.73.92Kleinfelder
S0546825S133465-80.153426774059728.34.7Kleinfelder
S0546825S133463-10.153434604087328.94.19Kleinfelder
S0546825S133462-40.153438584083028.84.25Kleinfelder
S0546825S133463-60.153437794121930.03.74Kleinfelder
S0546825S133462-10.153436934102629.24.67Kleinfelder
S0546825S133462-30.153433824096628.84.93Kleinfelder
S0546825S133464-30.153432964072928.73.77Kleinfelder
S0546825S133464-70.153431674069628.93.95Kleinfelder
UTM NA
Temperature 0 f
Extensometers NA