Sample Record for 2026-03-12-31
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995065 DEA: 112N1764
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-8-R50.3/R96.7
Work Description: MICROSURFACING, SHOULDER BACKING, PAVEMENT MARKING, & INSTALL SIGNS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM 0.2 MILE WEST OF BONDS CORNER OVERCROSSING TO 0.2 MILE EAST OF FOURTH AVENUE OVERCROSSING .
Contractor Name: PAVEMENT COATINGS CO.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2026-03-12-31
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 03/12/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/13/2026
The quantity of what the sample constitutes: 5 bags
A brief description of the sample: JMFR
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: API Gateway
Material Information
Source Identification (SMARA, name of Pit or Job Site): See Mix
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 40 API Val
Test Results
Test
DIME Test ID: 2026-03-12-31-4
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Combined Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
70 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
11 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
2 %
|
|
Cumulative percent passing the #4 sieve
|
no data0 %
|
|
Cumulative percent passing the #8 sieve
|
no data0 %
|
|
Cumulative percent passing the #16 sieve
|
no data0 %
|
|
Cumulative percent passing the #30 sieve
|
no data0 %
|
|
Cumulative percent passing the #50 sieve
|
no data0 %
|
|
Cumulative percent passing the #100 sieve
|
no data0 %
|
|
Cumulative percent passing the #200 sieve
|
no data0 %
|
Test
DIME Test ID: 2026-03-12-31-5
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Combined Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
59 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
9 %
|
|
Cumulative percent passing the #4 sieve
|
no data0 %
|
|
Cumulative percent passing the #8 sieve
|
no data0 %
|
|
Cumulative percent passing the #16 sieve
|
no data0 %
|
|
Cumulative percent passing the #30 sieve
|
no data0 %
|
|
Cumulative percent passing the #50 sieve
|
no data0 %
|
|
Cumulative percent passing the #100 sieve
|
no data0 %
|
|
Cumulative percent passing the #200 sieve
|
no data0 %
|
Test
DIME Test ID: 2026-03-12-31-6
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Combined Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
86 %
|
|
Cumulative percent passing the #4 sieve
|
3 %
|
|
Cumulative percent passing the #8 sieve
|
no data0 %
|
|
Cumulative percent passing the #16 sieve
|
no data0 %
|
|
Cumulative percent passing the #30 sieve
|
no data0 %
|
|
Cumulative percent passing the #50 sieve
|
no data0 %
|
|
Cumulative percent passing the #100 sieve
|
no data0 %
|
|
Cumulative percent passing the #200 sieve
|
no data0 %
|
Test
DIME Test ID: 2026-03-12-31-13
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Fine Aggregate
|
|
Total mass of sample tested
|
355.4 grams
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
100 %
|
|
Cumulative percent passing the #8 sieve
|
9 %
|
|
Cumulative percent passing the #16 sieve
|
1 %
|
|
Cumulative percent passing the #30 sieve
|
1 %
|
|
Cumulative percent passing the #50 sieve
|
1 %
|
|
Cumulative percent passing the #100 sieve
|
1 %
|
|
Cumulative percent passing the #200 sieve
|
0.5 %
|
Test
DIME Test ID: 2026-03-12-31-7
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Fine Aggregate
|
|
Total mass of sample tested
|
375.8 grams
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
100 %
|
|
Cumulative percent passing the #8 sieve
|
87 %
|
|
Cumulative percent passing the #16 sieve
|
55 %
|
|
Cumulative percent passing the #30 sieve
|
38 %
|
|
Cumulative percent passing the #50 sieve
|
25 %
|
|
Cumulative percent passing the #100 sieve
|
12 %
|
|
Cumulative percent passing the #200 sieve
|
6.7 %
|
Test
DIME Test ID: 2026-03-12-31-18
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Fine Aggregate
|
|
Total mass of sample tested
|
100 grams
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
100 %
|
|
Cumulative percent passing the #8 sieve
|
100 %
|
|
Cumulative percent passing the #16 sieve
|
100 %
|
|
Cumulative percent passing the #30 sieve
|
99 %
|
|
Cumulative percent passing the #50 sieve
|
95 %
|
|
Cumulative percent passing the #100 sieve
|
81 %
|
|
Cumulative percent passing the #200 sieve
|
72.2 %
|
Test
DIME Test ID: 2026-03-12-31-2
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Method
|
B
|
|
Determination
|
By Number
|
|
Dimensional ratio used
|
5:1
|
|
Weighted percentage of particles (by number) that were flat and elongated
|
0 %
|
|
Weighted percentage of particles (by number) that were not flat and elongated
|
0 %
|
Test
DIME Test ID: 2026-03-12-31-9
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Basis for relative density testing
|
Bulk
|
|
Specific Gravity
|
2.666
|
|
Absorption
|
0.6 %
|
Test
DIME Test ID: 2026-03-12-31-8
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk specific gravity
|
2.604
|
|
Bulk specific gravity (SSD Basis)
|
2.633
|
|
Apparent specific gravity
|
2.682
|
|
Absorption
|
1.1 %
|
Test
DIME Test ID: 2026-03-12-31-11
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Grading designation
|
B
|
|
Mass of sample on No.12 sieve (after 500 revolutions)
|
3151 grams
|
|
Percent loss after 100 revolutions
|
9 %
|
|
Percent loss after 500 revolutions
|
37 %
|
Test
DIME Test ID: 2026-03-12-31-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Test
DIME Test ID: 2026-03-12-31-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Method
|
1 - Combined Fracture Determination
|
|
Aggregate Size and Fracture Type
|
Coarse 2 Faced and Fine 1 Faced
|
|
Percentage of questionable, coarse, 2 faced particles tested
|
no data0 %
|
|
Percentage of questionable, fine, 1 faced particles tested
|
no data0 %
|
|
Percentage of fractured, coarse, 2 faced particles tested
|
100 %
|
|
Percentage of fractured, fine, 1 faced particles tested
|
100 %
|
Test
DIME Test ID: 2026-03-12-31-10
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 03/25/2026
Date Tested: 03/19/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
What test method is performed?
|
Method A
|
|
Bulk dry specific gravity
|
2.604
|
|
Average uncompacted voids
|
45.5 %
|
Test
DIME Test ID: 2026-03-12-31-19
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: D11PlantServices@dot.ca.gov
Organization Phone: (858) 518-8709
This test has been superseded on 04/07/2026.
Reason: retested
Test
DIME Test ID: 2026-03-12-31-20
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 04/07/2026
Date Tested: 04/01/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Oven 3
Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
0.5 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
-1 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-4.5 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
-5 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
-4.5 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
-2.5 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-1.5 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-1.5 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.6 %
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
86 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
67 %
|
|
Cumulative percent passing the #4 sieve
|
24 %
|
|
Cumulative percent passing the #8 sieve
|
10 %
|
|
Cumulative percent passing the #16 sieve
|
10 %
|
|
Cumulative percent passing the #30 sieve
|
5 %
|
|
Cumulative percent passing the #50 sieve
|
3 %
|
|
Cumulative percent passing the #100 sieve
|
1 %
|
|
Cumulative percent passing the #200 sieve
|
1.3 %
|