Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2026-01-30-30
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/30/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/09/2026
The quantity of what the sample constitutes: 3400
A brief description of the sample: 5/8-11x2 A325 HEX BOLT HDG
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fontana Gruppo
Rocap Number(s): NA
Heat Number(s): 10978760
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: ASTM A325
Bolt Length(s): 2"
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 5/8-11X2
Bolt Mfg. Lot Number: E725W1
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA
Washer Inner Diameter(s): NA
DIME Test ID: 2026-01-30-30-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/24/2026
Date Tested: 03/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5735 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-01-30-30-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/24/2026
Date Tested: 03/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5740 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-01-30-30-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/24/2026
Date Tested: 03/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5765 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-01-30-30-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/24/2026
Date Tested: 03/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5765 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-01-30-30-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/24/2026
Date Tested: 04/21/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.4 mils
|
DIME Test ID: 2026-01-30-30-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/24/2026
Date Tested: 04/21/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.6 mils
|
DIME Test ID: 2026-01-30-30-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/24/2026
Date Tested: 04/21/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3 mils
|
DIME Test ID: 2026-01-30-30-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/24/2026
Date Tested: 04/21/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E725W1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.9 mils
|
DIME Test ID: 2026-01-30-30-9
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 04/24/2026
Date Tested: 04/21/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Bolt Samples
|
4
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | E725W1 | 0.625 | 31950 | 0 | 0 | NA | Atlas | | 1B | E725W1 | 0.625 | 32300 | 0 | 0 | NA | Atlas | | 1C | E725W1 | 0.625 | 32020 | 0 | 0 | NA | Atlas | | 1D | E725W1 | 0.625 | 32060 | 0 | 0 | NA | Atlas |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|