Project Information

Project ID: 995493 DEA: 081G6704 EFIS: 0816000049 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-79-5.4/11.4
Work Description: HOT MIX ASPHALT, SOIL NAIL, STRUCTURAL CONCRETE AND ROADWAY EXC.
Location Description: RIVERSIDE COUNTY NEAR TEMECULA FROM 0.4 MILE SOUTH OF SAGE ROAD TO 1.1 MILES SOUTH OF PAUBA ROAD
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 CUSHING STE 200, IRVINE, CA 92618
Resident Engineer: Osama Abdalla Structure Rep.: Arnel Vega

Sample Information

DIME Sample ID: 2026-03-05-18
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 03/05/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/06/2026
The quantity of what the sample constitutes: 1
A brief description of the sample: .6 PT Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden

Material Information

Comments:
Reel/Coil/Pack Number(s): S337073-1
Number of Coils:
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0554125
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden

Test Results

Test

DIME Test ID: 2026-03-05-18-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 03/26/2026
Date Tested: 03/26/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0554125S337073-10.217602155744429.30000AEC
UTM NA
Temperature 0 f
Extensometers NA