Print Report | Back to Sample Detail

Sample Record for 2025-08-11-96

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995494 DEA: 081K4904 EFIS: 0819000050 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R105.1/R105.9
Work Description: BUILDING WORK, HMA, AND TEMPORARY PORTABLE SANITARY FACILITIES.
Location Description: SAN BERNARDINO COUNTY ABOUT 36 MILES WEST OF NEEDLES FROM 2.1 MILES TO 1.3 MILES WEST OF GOFFS ROAD UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 38000 Monroe Street, Indio, CA 92203
Resident Engineer: Anthony Doan Structure Rep.: Alejandrino Naime

Sample Information

DIME Sample ID: 2025-08-11-96
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/12/2025
The quantity of what the sample constitutes: 1 per batch
A brief description of the sample: CIP concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hi-Grade

Material Information

The concrete mix design number: CT752F25
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 34004019
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: westbound comfort station B
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-08-11-96-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/04/2026
Date Tested: 09/08/2025
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4460 psi
Maximum load on cylinder 1 125240 lb
Maximum load on cylinder 2 127130 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours