Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-40.5/42.7
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd., Livermore, CA
Resident Engineer: Mahfual Alam Structure Rep.: Unknown
DIME Sample ID: 2026-02-20-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/20/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/21/2026
The quantity of what the sample constitutes: 3 Sets of 3 - 6X6X21 Rapid Set Concrete Beams
A brief description of the sample: Set 1 Fabricated @ 23:00(2/20); Set 2 Fabricated @ 01:53(2/21); Set 3 Fabricated @ 04:27(2/21)
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard
The concrete mix design number: HE4X4BM
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Concrete Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2026-02-20-16-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 03/02/2026
Date Tested: 02/24/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set #61-1
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
3
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Fracture occurred at a capped section
|
No
|
|
Is a beam dimensional correction factor used?
|
No
|
|
Age of specimen
|
4 days
|
|
Modulus of rupture
|
890 psi
|
|
Modulus of rupture 2
|
780 psi
|
|
Modulus of rupture average
|
900 psi
|
|
Modulus of rupture 3
|
1030 psi
|
DIME Test ID: 2026-02-20-16-2
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 03/02/2026
Date Tested: 02/24/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set #61-2
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
3
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Fracture occurred at a capped section
|
No
|
|
Is a beam dimensional correction factor used?
|
No
|
|
Age of specimen
|
3 days
|
|
Modulus of rupture
|
1010 psi
|
|
Modulus of rupture 2
|
980 psi
|
|
Modulus of rupture average
|
1020 psi
|
|
Modulus of rupture 3
|
1080 psi
|
DIME Test ID: 2026-02-20-16-3
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 03/02/2026
Date Tested: 02/24/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set #61-3
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
3
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Fracture occurred at a capped section
|
No
|
|
Is a beam dimensional correction factor used?
|
No
|
|
Age of specimen
|
3 days
|
|
Modulus of rupture
|
1000 psi
|
|
Modulus of rupture 2
|
950 psi
|
|
Modulus of rupture average
|
960 psi
|
|
Modulus of rupture 3
|
920 psi
|