Print Report | Back to Sample Detail

Sample Record for 2026-03-01-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez

Sample Information

DIME Sample ID: 2026-03-01-1
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/01/2026
Date that the sample was received by the laboratory/organization performing the testing: 03/02/2026
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: PSU
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Lakeside

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 23418180AH
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier: Valero
RAP content (%): 0
WMA Additives: No
Antistrip type:

Test Results

Test

DIME Test ID: 2026-03-01-1-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/05/2026
Date Tested: 03/02/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4039.9 g
Mass of the specimen and specimen basket assembly prior to ignition 6063.9 g
Mass of HMA Sample prior to ignition 2024 g
Corrected Asphalt Binder Content 7.89 %
Mass Loss 161.7 g
Mass of aggregate remaining after ignition 1862.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.1 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test

DIME Test ID: 2026-03-01-1-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/05/2026
Date Tested: 03/02/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2525.7 grams
Mass of container filled with the sample and water for Sample 1 8967.7 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.444
Theoretical maximum density at 25°C (77°F) 152.1 lb/ft^3

Test

DIME Test ID: 2026-03-01-1-5
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 03/05/2026
Date Tested: 03/05/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm Tested an Avg of 2.19 mm
Test Result Compliance: complies
Additional Comments When Verified:
Specimen Preparation Method PMLC
Test Temperature 122 F
Air Void Content for specimen A-1 6.1 %
Air Void Content for specimen A-2 6 %
Air Void Content for specimen B-1 6.2 %
Air Void Content for specimen B-2 6.1 %
Stripping Inflection Point (Wheel A) >15000
Stripping Inflection Point (Wheel B) >15000
Maximum impression at 5000 passes (left wheel) 0.68 mm
Maximum impression at 5000 passes (right wheel) 0.85 mm
Average impression at 5000 passes (left/right avg) 0.77 mm
Maximum impression at 10000 passes (left wheel) 1.4 mm
Maximum impression at 10000 passes (right wheel) 1.65 mm
Average impression at 10000 passes (left/right avg) 1.53 mm
Maximum impression at 15000 passes (left wheel) 1.94 mm
Maximum impression at 15000 passes (right wheel) 2.44 mm
Average impression at 15000 passes (left/right avg) 2.19 mm
Average impression at 20000 passes (left/right avg) no data
Average impression at 25000 passes (left/right avg) no data

Test

DIME Test ID: 2026-03-01-1-6
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 03/05/2026
Date Tested: 03/03/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.387
Bulk Specific Gravity 2 2.395
Bulk Specific Gravity 3 2.395
Average Bulk Specific Gravity 2.392

Test

DIME Test ID: 2026-03-01-1-7
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 03/05/2026
Date Tested: 03/03/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does Not Comply
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids 2.3 %
Percent Air Voids 2 2 %
Percent Air Voids 3 2 %
Average Percent Air Voids 2.1 %