Print Report | Back to Sample Detail

Sample Record for 2026-01-27-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000641 DEA: 080G8504 EFIS: 0815000218 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R71.2/R72.6
Work Description: BUILDING WORK.
Location Description: RIVERSIDE COUNTY NEAR INDIO FROM 0.9 MILE WEST TO 0.5 MILE EAST OF THE CACTUS CITY SAFETY ROADSIDE REST AREAS
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 38000 Monroe Street, Indio, CA 92203
Resident Engineer: Khoi Vu Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-01-27-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/02/2026
The quantity of what the sample constitutes: 2 boxs
A brief description of the sample: 3/4 HMA-SP Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Company

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2026-01-27-37-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/23/2026
Date Tested: 02/02/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Corrected Asphalt Binder Content 4.19 %
Mass of HMA Sample prior to ignition 2164.4 g
Mass Loss 93.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.01 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C