Print Report | Back to Sample Detail

Sample Record for 2026-02-09-52

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993678 DEA: 042Q8004 EFIS: 0419000050 COOP: 042836,042944 QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101,92-US 101 & SR 92-10.9/12.1 & 11.8/13.4
Work Description: US 101/SR 92 INTERCHANGE AREA IMPROVEMENT :PROJECT WILL CONSTRUCT CONGESTION RELIEF IMPROVEMENTS AT THE US 101/SR 92 INTERCHANGE AREA.
Location Description:
Contractor Name: GORDON N. BALL, INC.
Contractor Address: 333 CAMILLE AVENUE, ALAMO, CA 94507
Resident Engineer: Mohamed Fouad Structure Rep.: Bryan Nagid

Sample Information

DIME Sample ID: 2026-02-09-52
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3674 - Pacifica 2
Sample Organization Contact: (510) 714-7639
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/09/2026
Date that the sample was received by the laboratory/organization performing the testing: 12/16/2025
The quantity of what the sample constitutes: 2
A brief description of the sample: Structural concrete (5,000psi)
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: WS Ramp (Widen)
The fabricator/manufacturer/facility name: Graniterock Redwood City batch plant

Material Information

The concrete mix design number: 07S802
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant: Graniterock Redwood City
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete sampled from truck chute
Where the material sample would have been placed if not sampled: Hinge lower seat
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-02-09-52-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/04/2026
Date Tested: 03/02/2026
Submitted By Organization: Quality Assurance Engineering, Inc dba Consolidated Engineering Laboratories
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: Set of three cylinders. original break scheduled for 14 days, changed to 21. B.O.
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 8710 psi
Maximum load on cylinder 1 108760 lb
Maximum load on cylinder 2 110280 lb
Maximum load on cylinder 3 109630 lb
Compressive strength of cylinder 1 8650.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 8770.0 psi
Compressive strength of cylinder 3 8720 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 21 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-02-09-52-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/17/2026
Date Tested: 03/09/2026
Submitted By Organization: Quality Assurance Engineering, Inc dba Consolidated Engineering Laboratories
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 8730 psi
Maximum load on cylinder 1 109190 lb
Maximum load on cylinder 2 110230 lb
Maximum load on cylinder 3 109680 lb
Compressive strength of cylinder 1 8690.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 8770.0 psi
Compressive strength of cylinder 3 8730 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data