Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000199 DEA: 050N7054 EFIS: 0518000111
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-10.4/11.1
Work Description: South Coast 101 HOV Lanes Project 4E South- Santa Barbara
Location Description:
Contractor Name: Granite Construction Company
Contractor Address: PO Box 6744, Santa Barbara, CA 93160
Resident Engineer: Luobao Cai Structure Rep.: Faris Malik
DIME Sample ID: 2026-02-13-39
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Sample Organization Contact: (805) 621-3616
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 02/13/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/17/2026
The quantity of what the sample constitutes: 100 Tons
A brief description of the sample: 3/4 HMA SP R25
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Santa Paula
DIME Test ID: 2026-02-13-39-3
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/20/2026
Date Tested: 02/18/2026
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: daniel.gingras@dot.ca.gov
Organization Phone: (805) 549-3141
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3888.4 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5897.7 g
|
|
Corrected Asphalt Binder Content
|
4.63 %
|
|
Mass of HMA Sample prior to ignition
|
2009.3 g
|
|
Mass Loss
|
107.2 g
|
|
Mass of aggregate remaining after ignition
|
1902.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.71 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|