Project ID: 1000603 DEA: 051K4504 EFIS: 0518000209
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-R52.3/R56.1
Work Description: COLD PLANE AND RHMA/HMA ROADWAY AND BRIDGE, & REPLACE CULVERTS.
Location Description: SANTA BARBARA COUNTY NEAR BUELLTON FROM OLD COAST HIGHWAY TO 0.4 MILE SOUTH OF SANTA ROSA ROAD OVERCROSSING
Contractor Name: CALPORTLAND CONSTRUCTION
Contractor Address: Unknown
Resident Engineer: Jason Torres Structure Rep.: Cliff Raplogle
DIME Sample ID: 2026-02-11-13
TL Number from the TL Form: 200KBP
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 02/11/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/12/2026
The quantity of what the sample constitutes: 34 Totes
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 26-003
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2026-02-11-13-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 03/19/2026
Date Tested: 03/19/2026
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2026-02-11-13-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 03/19/2026
Date Tested: 03/19/2026
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Density Units
|
pounds/gallons
|
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2026-02-11-13-3
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 03/19/2026
Date Tested: 03/19/2026
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Mean of two volatile content determination
|
46
|
DIME Test ID: 2026-02-11-13-4
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 03/19/2026
Date Tested: 03/18/2026
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.528 in
|
|
Sample 1 Ultimate strength
|
2738.9 psi
|
|
Sample 1 Thickness
|
0.222 in
|
|
Sample 1 Area
|
0.1172 in^2
|
|
Sample 1 Ultimate Strength Actual
|
321 lbs
|
|
Sample 1 percent elongation
|
61 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.509 in
|
|
Sample 2 Thickness
|
0.232 in
|
|
Sample 2 Area
|
0.1181 in^2
|
|
Sample 2 Ultimate strength
|
2802.7 psi
|
|
Sample 2 Ultimate Strength Actual
|
331 lbs
|
|
Sample 2 percent elongation
|
60 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.516 in
|
|
Sample 3 Thickness
|
0.229 in
|
|
Sample 3 Area
|
0.1182 in^2
|
|
Sample 3 Ultimate strength
|
2808.8 psi
|
|
Sample 3 Ultimate Strength Actual
|
332 lbs
|
|
Sample 3 percent elongation
|
63 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.506 in
|
|
Sample 4 Thickness
|
0.234 in
|
|
Sample 4 Area
|
0.1184 in^2
|
|
Sample 4 Ultimate strength
|
2643.6 psi
|
|
Sample 4 Ultimate Strength Actual
|
313 lbs
|
|
Sample 4 percent elongation
|
55 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.516 in
|
|
Sample 5 Thickness
|
0.228 in
|
|
Sample 5 Area
|
0.1176 in^2
|
|
Sample 5 Ultimate strength
|
3018.7 psi
|
|
Sample 5 Ultimate Strength Actual
|
355 lbs
|
|
Sample 5 percent elongation
|
55 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.511 in
|
|
Sample 6 Thickness
|
0.226 in
|
|
Sample 6 Area
|
0.1155 in^2
|
|
Sample 6 Ultimate strength
|
2744.6 psi
|
|
Sample 6 Ultimate Strength Actual
|
317 lbs
|
|
Sample 6 percent elongation
|
62 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
2793 psi
|
|
Percent Elongation Average
|
59 %
|
DIME Test ID: 2026-02-11-13-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 03/19/2026
Date Tested: 02/19/2026
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test: Accepted based on supplier's result.
Test Result Compliance: complies
Additional Comments When Verified:
|
Curing history for Sample 1
|
24hr
|
|
Maximum applied load (P) for Sample 1
|
1312 lb
|
|
Span length for Sample 1
|
9 in
|
|
Break location for Sample 1
|
bond
|
|
Specimen defects/notes for Sample 1
|
no data
|
|
Surface type for Sample 1
|
SSD
|
|
Modulus of rupture (R) for Sample 1
|
656 psi
|
|
Curing history for Sample 2
|
24hr
|
|
Maximum applied load (P) for Sample 2
|
1500 lb
|
|
Span length for Sample 2
|
9 in
|
|
Break location for Sample 2
|
bond
|
|
Specimen defects/notes for Sample 2
|
no data
|
|
Surface type for Sample 2
|
SSD
|
|
Modulus of rupture (R) for Sample 2
|
750 psi
|
|
Curing history for Sample 3
|
24hr
|
|
Maximum applied load (P) for Sample 3
|
1272 lb
|
|
Span length for Sample 3
|
9 in
|
|
Break location for Sample 3
|
bond
|
|
Specimen defects/notes for Sample 3
|
no data
|
|
Surface type for Sample 3
|
SSD
|
|
Modulus of rupture (R) for Sample 3
|
636 psi
|
DIME Test ID: 2026-02-11-13-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 03/19/2026
Date Tested: 03/19/2026
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Diameter of lid
|
144.98 mm
|
|
Room Temperature
|
73 f
|
|
Tare weight
|
no data
|
|
Initial weight
|
100.65 grams
|
|
Weight at 5 minutes
|
100.47 grams
|
|
Weight at 10 minutes
|
100.3 grams
|
|
Weight at 15 minutes
|
100.16 grams
|
|
Weight at 20 minutes
|
100.04 grams
|
|
Weight at 25 minutes
|
99.94 grams
|
|
Weight at 30 minutes
|
99.87 grams
|
|
Final weight
|
99.87 grams
|
|
Total weight loss
|
0.78 grams
|
|
Calculated radius of gallon can lid in cm
|
7.249 cm
|
|
Lid Factor
|
60.575 m^2
|
|
Volatile emission
|
47.249 grams/m^2
|